WF-10T
Case Former
Operating Procedures
6-47
6.4
Clearing a Case Jam
The WEXXAR Model WF-10T Case Formers will provide reliable, trouble-free performance on a
wide variety of case sizes. Occasional jams are not uncommon, but frequent jamming can
usually be traced to a particular reason, such as incorrectly set machine adjustment, and
corrected. Refer to Section 7:
Section 8.5:
and Section 9:
for further information.
To place the machine back into service as quickly as possible after a jam has occurred, proceed
as follows:
1.
Press one of the ‘EMERGENCY STOP’ buttons
. This will shut off the electrical and air
power to the machine mechanisms. It may take a few moments for the system air
pressure to decline to zero;
wait approximately 3 seconds, or until air pressure has
fully exhausted and all mechanisms are stationary before proceeding.
2. If required by local regulations or company policy, lock out the electrical power and air
supply before proceeding.
3. Open the guard door for access to the jammed case.
4. Remove all jammed case corrugate. Any mechanism that is entangled with the jammed
case may safely be moved by hand, as all air pressure has been exhausted.
5. Close the guard door and pull out the
‘EMERGENCY STOP’
button. Remove lock-out, if
applicable.
6. Press
the
‘RESET’
button and restart the machine by following the start-up procedure in
7. After clearing all mechanisms to their
HOME
positions when the machine is restarted.
Refer to Section 6.2.2:
Check the ‘S’ box for Satisfactory Performance and ‘US’ box for Unsatisfactory Performance.
Table 9: Clearing Jams
Clearing Jams
S
US
Press the
‘EMERGENCY STOP’
button.
Wait until air pressure has fully exhausted and all mechanisms are
stationary before proceeding.
Open the guard door for access to the jammed case.
Remove all jammed case corrugate by hand.
Close the guard door.
Reset the
‘EMERGENCY STOP’
button.
Press the
‘RESET’
button.
Restart the machine.
Summary of Contents for WF-10T
Page 2: ...WF 10T Case Former ...
Page 118: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 106 ...
Page 119: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 107 ...
Page 120: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 108 ...
Page 121: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 109 ...
Page 122: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 110 ...
Page 123: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 111 ...
Page 125: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 113 ...
Page 126: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 114 ...
Page 127: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 115 ...
Page 128: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 116 ...
Page 129: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 117 ...