Installation instructions
15
3.5.4
Steam (optional)
A shut-off cock must be installed on the incoming pipe (4). The required steam
pressure can be found in the TECHNICAL SPECIFICATIONS.
3.5.5
Condensation water (option)
A condensation connection (5) is only provided on steam-heated machines. The
pipe is connected to the system’s steam boiler.
3.5.6
Drain/waste pipe connection
The waste water system connected to (6) should use 50 mm metal pipes that tol-
erate mechanical collision. The waste pipe is routed to a floor drain with the pipe
exit kept clear of the water level.
Ensure that the drain connection is kept in place by using e.g. cable ties in the
designated areas.