Westinghouse WPAC10000 User Manual Download Page 9

Westinghouse Outdoor Power Equipment | 9

INSTALLATION

3. 

Run the exhaust duct outdoors.

4. 

If using a window vent, install it following the instructions 

below. 

INSTALL THE WINDOW VENT KIT

Part no: 600005064431

INCLUDED PARTS 

Adjustment panel

Window panel

Exhaust cover

Extension panel

Screen

Rain guard

Fixed base

Fixed clip

Mounting plate 

 

Bracket (1)

Screw (1)

Foam seal A

Foam seal B 

(adhesive type)

SUGGESTED TOOLS

• 

Screwdriver (medium size Phillips)

•  Tape measure or ruler
•  Knife or scissors
•  Saw (In the event that the window panel needs to be 

cut down in size because the window is too narrow for 

direct installation.)

INSTALL WINDOW PANEL

1. 

Open the window and measure the width or height 

inside the window frame. Cut the foam seal B to the 

proper length and attach it to your horizontal (or vertical) 

sliding window.

Foam seal B

(adhesive type)

Foam seal B

(adhesive type)

Width

Height

2. 

Attach the screen to the back side of the window panel. 

Push the screen securely into the window panel to 

ensure that is firmly installed.

3. 

Insert the exhaust cover to the window panel.

Insert the first groove

Summary of Contents for WPAC10000

Page 1: ...USER MANUAL Portable Room Air Conditioner Models WPAC8000 WPAC10000 DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571...

Page 2: ...wed in any form without written permission from Westinghouse Outdoor Power Equipment Read this manual before using or performing maintenance on this product Failure to follow the instructions and safe...

Page 3: ...MANUAL FOR FUTURE REFERENCE PRODUCT REGISTRATION For trouble free warranty coverage it is important to register your Westinghouse generator You can register by Completing and mailing the product regis...

Page 4: ...out the power plug Ensure that the power cord is undamaged Do not pull or drag the power cord to pull out the power plug or move the air conditioner Do not insert or pull out the power plug with wet h...

Page 5: ...lso lower R32 has very good thermodynamic features and high energy efficiency The units therefore need less filling Appliance filled with flammable gas R32 Appliance shall be installed operated and st...

Page 6: ...tdoor Power Equipment INSTALLATION INSTALLATION UNIT OVERVIEW 2 5 Louver vent Exhaust connector 1 Control panel 1 2 3 4 7 6 3 Caster 4 Filter 5 8 9 Remote control 6 Exhaust duct 7 Window clip 8 Power...

Page 7: ...as far away as possible from fluorescent lighting Do not install in laundry area POWER REQUIREMENTS Follow all electrical safety regulations when installing the unit Use a qualified power supply circ...

Page 8: ...ly Do not operate the air conditioner in a humid environment Keep air inlet and air outlet clean and free of obstacles Reserved space around the air conditioner 30cm 12 inches INSTALL EXHAUST DUCT Whe...

Page 9: ...Tape measure or ruler Knife or scissors Saw In the event that the window panel needs to be cut down in size because the window is too narrow for direct installation INSTALL WINDOW PANEL 1 Open the wi...

Page 10: ...gth of window panel please use the adjustment panel to make sure you can span the entire length of your window Otherwise you can add an extension panel to prolong the length of the windows panel assem...

Page 11: ...place unit on a level surface and make sure the hose is clear of any obstructions and directed downward Placing unit on an uneven surface or improper hose installation may result in water filling up t...

Page 12: ...dry batteries 3 Reinstall the cover of battery box Reinstall Signal sender Battery Remove Cover of battery box TEST OPERATION 1 Plug in the power supply 2 Press ON OFF button on remote control to star...

Page 13: ...will increase or decrease 0 5 hour by pressing or button within 10 hours while timer setting will increase or decrease 1 hour by pressing or button beyond 10 hours After timer setting is finished the...

Page 14: ...to Low Med or High 2 Buttons In cooling mode press or button to increase or decrease set temperature by 1 F C 3 Cool Mode Press to change operation to Cool mode 4 ON OFF Press this button to turn on o...

Page 15: ...e front of the unit Adjust this louver to direct air flow 2 Press the ON OFF button from the remote or from the control panel to start the unit 3 Select operating mode Cool Fan or Dry 4 In cooling mod...

Page 16: ...hen put it in a shady place to dry it 3 After the filter is cleaned and dried reinstall it CLEAN EXHAUST DUCT 1 Remove the exhaust duct from air conditioner clean and dry it and then reinstall it EMPT...

Page 17: ...lease maintain it by following steps for good performance 1 Make sure there s no accumulated water in chassis and the exhaust duct is disassembled 2 Pull out the plug and wrap the power cord 3 Clean t...

Page 18: ...g the unit wait three 3 minutes plug in again and then turn on the unit Remote control is not within receiving range The receiving range of remote control is 8 meters Do not exceed this range The rece...

Page 19: ...o high pow er off the unit and then energize it for operation after the ambient temperature drops to 95 F 35 C below Check if the evaporator and condenser are blocked by some objects if yes take away...

Page 20: ...ould a product difficulty occur you must at your expense deliver or ship your Westinghouse Outdoor Power Equipment LLC unit to an Authorized Service Dealer for warranty repairs which must occur within...

Page 21: ...le Air Conditioners and its affiliated companies shall not be liable for any special incidental or consequential damage including lost profits There are no warranties extended other than as provided h...

Page 22: ...seOutdoorPower com and Westinghouse are trademarks of Westinghouse Electric Corportaion Used under license by Westinghouse Outdoor Power Equipment All Rights Reserved WPAC8000 WPAC10000 66139902592 Re...

Reviews: