41
WHL-015 REV. 1.13.17
This appliance is equipped with a three prong plug. It should only be plugged directly into a properly grounded three prong receptacle.
DO NOT remove the ground plug from the plug. Doing so could result in property damage, serious personal injury, or death.
2. The wiring diagrams contained in this manual are to be used for reference purposes only.
3. Refer to these diagrams and the wiring diagrams of any external controls used with the installation when wiring the appliance. Read,
understand, and follow all wiring instructions supplied with the controls.
4. Do not disconnect the power supply when the appliance is in normal operation.
NOTE:
For additional electrical protection, the use of a surge protector is recommended. Damage caused by power surges is not
covered by the warranty.
Figure 27
– Manual Power Switch and Appliance Plug Details
NOTICE
If the appliance display does not come ON, first check the plug. Then check the electrical panel circuit breaker and reset it if necessary.
If the circuit breaker trips again, do not reset. Disconnect the plug and have a qualified technician diagnose the problem.
C. DIP SWITCHES
There is one set of DIP switches. The applia
nce is default set at the factory to operate on Natural Gas with a 3” vent.
Figure 28
– Dip Switch Detail
DIP SWITCH GROUP
DIP SWITCH
OFF
ON
1
– 3
DO NOT MOVE
DO NOT MOVE
4
Vent Size
2”
3
”
5
Gas Type
LP
NG
6
High Fire
Normal Operation
High Fire
7
Low Fire
Normal Operation
Low Fire
Table 19
– DIP Switch Group
Summary of Contents for WBRC 140F Series
Page 2: ...2 WHL 015 REV 1 13 17 ...
Page 43: ...43 WHL 015 REV 1 13 17 Figure 29 140F Model Electrical Wiring Diagram ...
Page 44: ...44 WHL 015 REV 1 13 17 Figure 30 140F Model Ladder Diagram ...
Page 45: ...45 WHL 015 REV 1 13 17 Figure 31 199F Model Electrical Wiring Diagram ...
Page 46: ...46 WHL 015 REV 1 13 17 Figure 32 199F Model Ladder Diagram ...