WESTERSTRAND
Document: DOK11018en02
Author: PM/CF
Analogue NTP Clock
Date: 2020-09-24
Page: 12 of 21
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
NTP server
Select NTP servers, e.g.
192.168.1.237
or as an URL
ntp.se
. Also see
NTP mode
=DHCP above
Up to five different NTP servers can be entered. If the first one fails it will automatically go to the
next one and so on.
Set local Time
Used for manual time setting.
Interval
Interval in seconds between NTP requests.
Reset hands at time out
This function is used to define how the clock should behave during a NTP synchronization alarm. See Alarm
timeout below. If the checkbox is checked the clock hands will go to 12 in case of synchronization alarm. If the box
is not checked, the clock continues to show time and uses its own built-in quartz oscillator as time reference.
Alarm timeout.
Time in minutes before the NTP synchronization alarm is activated.
Timezone
Select country/time zone. A NTP server sends UTC time. The clock will correct this to local time. If Daylight
Saving Time (see below) is checked it will also and adjust for DST (Daylight Saving Time) automatically.
Daylight Saving Time
If checked then this timezone uses DST (Daylight Saving Time).