background image

 

 

Document:  1867en10.doc 

 

Auth.:  TAn 

 

 

Date:  2016-11-07 

 

Page:  1 of 16 

 
 
 

 
WESTERSTRAND URFABRIK AB 

 

 

 

Box 133 

Tel.  0506 48 000 

 

Internet:: 

www.westerstrand.se 

545 23  TÖREBODA 

Fax. 0506 48 051 

 

E-mail: 

 [email protected]

 

 

 
 
 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Manual

 

 

Westerstrand T/T- display

 

 

 

 

Summary of Contents for 190100 Series

Page 1: ...10 doc Auth TAn Date 2016 11 07 Page 1 of 16 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Manual Westerstra...

Page 2: ...in 1 25 seconds intervals Consists of 7 segments LED digits in dimensions 150 190 250 300 and 450 mm The time and temperature display could be single or double sided with or without second One side c...

Page 3: ...isplay is turned off The internal clock continues to keep the correct time for 48 hours After the power failure the display is turned on and correct time is shown Installation Mount the clock by means...

Page 4: ...Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Connection Connection synchronisation TC and MIN imp is connected at IMP and IMP V IMP...

Page 5: ...07 Page 5 of 16 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Strapping TC MIN impulse computer board defaul...

Page 6: ...as follows Dip 1 OFF Display format is HH MM ON Display format is HH MM SS Dip 2 OFF always OFF Dip 3 OFF TC Min impulse synchronisation default ON DCF GPS synchronisation Dip 4 OFF TC Min impulse or...

Page 7: ...T T in slave mode InSL see programming page 10 Set time and wait for next minute impulse It is now working in slave mode TC Set the straps according to the strapping schema page 6 Connect the TC wire...

Page 8: ...of 16 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Connection temperature sensor option Temperature sensor...

Page 9: ...at the computer board Remote control R Return Enter the base mode display time F Function Next function Accept displayed value P Program Enter the displayed function Increase displayed value Manual p...

Page 10: ...isplay shows Setting light intensity The light intensity for the digits has one minimum and one maximum level The setting levels 1 50 are set in function disp An automatic dimmer function regulates th...

Page 11: ...se Push R for entering base mode or push F for next function Setting synchronisation Synchronisation for this model is minute impulse TC DCF GPS or stand alone Push F until display shows Push P for d...

Page 12: ...hows Alternating time for display temperature is 0 Push P for desired alternating temperature 0 25 Accept with F Display shows Alternating time for display date is 4 seconds Push P for desired alterna...

Page 13: ...ction the DLS can be activated Push F until display shows Push P Display shows Or Push P for DLS or not Push R for entering base mode or push F for next function Setting12 24 h format With this functi...

Page 14: ...e range temperature sensor 30 C 60 C Accuracy temperature sensor 1 C Temperature measurement Once per minute Specific for 190100 xx Type Single sided without second Connection current max 2A Size of d...

Page 15: ...HH MM SS 190mm 190mm 150mm Dimension WxHxD 1070x270x92mm 190131 xx Type Double sided with second Connection current max 2A Size of digits HH MM SS 190mm 190mm 150mm Dimension WxHxD 1070x270x130mm 190...

Page 16: ...161 xx Type Double sided without second Connection current max 2 5A Size of digits HH MM 300mm 300mm Dimension WxHxD 1000x380x130mm 190170 xx Type Single sided with second Connection current max 2 5A...

Reviews: