User Guide
5. System Management
5.3 Zoning
5.3
Zoning
5.3.1
Before Zoning
This section provides information on actions that should be taken before starting zoning on the Ultrastar
Data60.
Users should install all of the required downloads before beginning the zoning process.
Required Downloads
:
•
SMP Tools 0.98 for Linux:
http://sg.danny.cz/sg/smp_utils.html
•
http://sg.danny.cz/sg/sg3_utils.html
•
CLI Tools: to download the latest version of CLI tools, see:
Downloading Firmware from the Support
5.3.2
Predefined Zoning Configurations
There are three predefined zoning configurations for the Ultrastar Data60. Each configuration connects
a different number of hosts to a set number of drives. Each of these drives are part of a grouping called
a zone group. This section displays the necessary information related to each of the predefined zoning
configurations.
Configuration 0:
Configuration 0 allows all hosts to view all drive slots and the devices that are populated in those drive
slots. In this Configuration, all of the drives belong to the same zone group as shown in the image below
represented by one color. Each of the SAS ports on the rear IO of the enclosure are also represented by
one color to display their connection to all of the drives within the enclosure.
•
In-band management
: Configuration 0 can be initiated to disable zoning in the sg_senddiag
command in-band by using 00 in the Zoning Configuration option. See:
for the actual senddiag commands.
•
Out-of-band management
: Configuration 0 (default configuration) can be initiated to disable zoning
in the out-of-band management by using 0 in the ZoningConfig option. The following are example
Redfish POST and cURL commands:
182