![Western Digital ActiveScale P100 Support Manual Download Page 89](http://html1.mh-extra.com/html/western-digital/activescale-p100/activescale-p100_support-manual_960960089.webp)
ActiveScale™ P100 Support Guide
87
Table 6-1. Parts needed per system, per site
System
configuration
Uplink mode
Transceivers needed, per system, per site
Cables needed, per
system, per site
Type
Part number
Quanti
ty
ActiveScale
P100, base
system (one
column)
Mode 1 (two individual
10G access ports (48,47)
per System Interconnect)
SFP+ Finisar
FTLX8574D3B
CV-iT
1EX0272 (there
are 4 in each kit)
1
2 10Gb cables per System
Interconnect (4 cables
total)
Mode 2 (one 10G trunk
(port 48) per System
Interconnect)
SFP+ Finisar
FTLX8574D3B
CV-iT
1EX0279 (there
are 2 in each kit)
1
1 10Gb cable per System
Interconnect (2 cables
total)
Mode 3 (one 40G trunk
(port 50) per System
Interconnect)
QSFP+ ASM,
FINISAR 40G
QSFP+ SR
OPTIC,
FTL410QE3C
1EX0268 (there
is 1 in each kit)
2
1 40Gb cable per System
Interconnect (2 cables
total)
Mode 4 (three 10G trunks
(ports 48,47,46) with
LACP per System
Interconnect)
SFP+ Finisar
FTLX8574D3B
CV-iT
1EX0279 (there
are 2 in each kit)
3
3 10Gb cables per System
Interconnect (6 cables
total)
Mode 5 (two 40G trunks
(ports 50,52) with LACP
per System Interconnect)
QSFP+ ASM,
FINISAR 40G
QSFP+ SR
OPTIC,
FTL410QE3C
1EX0268 (there
is 1 in each kit)
2
2 40Gb cables per System
Interconnect (4 cables
total)
ActiveScale
P100, mid
system (two
columns)
Mode 1 (three individual
10G access ports
(48,47,45) per System
Interconnect)
SFP+ Finisar
FTLX8574D3B
CV-iT
1EX0272 and
1EX0279
1 of
each
3 10Gb cables per System
Interconnect (6 cables
total)
Mode 2 (one 10G trunk
(port 48) per System
Interconnect)
SFP+ Finisar
FTLX8574D3B
CV-iT
1EX0279 (there
are 2 in each kit)
1
1 10Gb cable per System
Interconnect (2 cables
total)
Mode 3 (one 40G trunk
(port 50) per System
Interconnect)
QSFP+ ASM,
FINISAR 40G
QSFP+ SR
OPTIC,
FTL410QE3C
1EX0268 (there
is 1 in each kit)
2
1 10Gb cable per System
Interconnect (2 cables
total)
Mode 4 (three 10G trunks
(ports 48,47,46) with
LACP per System
Interconnect)
SFP+ Finisar
FTLX8574D3B
CV-iT
1EX0272 and
1EX0279
1 of
each
3 10Gb cables per System
Interconnect (6 cables
total)
Mode 5 (two 40G trunks
(ports 50,52) with LACP
per System Interconnect)
QSFP+ ASM,
FINISAR 40G
QSFP+ SR
OPTIC,
FTL410QE3C
1EX0268 (there
is 1 in each kit)
2
2 40Gb cables per System
Interconnect (4 cables
total)
Summary of Contents for ActiveScale P100
Page 103: ...ActiveScale P100 Support Guide 101...
Page 104: ...ActiveScale P100 Support Guide 102...
Page 120: ...ActiveScale P100 Support Guide 118...
Page 124: ...ActiveScale P100 Support Guide 122...
Page 131: ...ActiveScale P100 Support Guide 129...
Page 132: ...ActiveScale P100 Support Guide 130...