4.3 User provided cables
To connect to the public network, the customer must provide networking cables that are compatible with
the SFP+ transceivers that are installed in the rear of each System Node. The transceivers require a multi-
mode, duplex, fiber optic cable (50/125) with an LC connector at the appliance end of the cable. The fiber
type of the cable will depend on the length of cable required. The rack to rack cable must be an OM3 MPO
Type-B female to female cable. If rack to rack connectivity uses the customer infrastructure, Type-A,
Type-B, or Type-C cables may be required.
Table 4-25. User provided cable length required
CN04
N4
CN4.N4.SW1.7
7
SW1
N3
CN4.N3.SW1.8
8
SW1
N2
CN4.N2.SW2.8
8
SW2
N1
CN4.N1.SW2.7
7
SW2
CN03
N4
CN3.N4.SW1.5
5
SW1
N3
CN3.N3.SW1.6
6
SW1
N2
CN3.N2.SW2.6
6
SW2
N1
CN3.N1.SW2.5
5
SW2
CN02
N4
CN2.N4.SW1.3
3
SW1
N3
CN2.N3.SW1.4
4
SW1
N2
CN2.N2.SW2.4
4
SW2
N1
CN2.N1.SW2.3
3
SW2
CN01
N4
CN1.N4.SW1.1
1
SW1
N3
CN1.N3.SW1.2
2
SW1
N2
CN1.N2.SW2.2
2
SW2
N1
CN1.N1.SW2.1
1
SW2
1.System Expansion Nodes use unlabeled cables.
Length needed to reach site network in meters
Fiber type needed
Up to 300
OM3 MPO Multi-mode fiber
Up to 400
OM4 MPO Multi-mode fiber
>400
Contact Western Digital Corporation support for options.
Table 4-24. System cabling (continued)
Local device
Local port
Full cable location
Peer port
Peer device
Summary of Contents for ActiveScale P100
Page 103: ...ActiveScale P100 Support Guide 101...
Page 104: ...ActiveScale P100 Support Guide 102...
Page 120: ...ActiveScale P100 Support Guide 118...
Page 124: ...ActiveScale P100 Support Guide 122...
Page 131: ...ActiveScale P100 Support Guide 129...
Page 132: ...ActiveScale P100 Support Guide 130...