background image

Industrial Ethernet

5-port Switch

www.westermo.com

©

W

estermo T

eleindustri 

AB 

• 

2005

User Guide

6644-2230

SDW-550

Summary of Contents for SDW-550 E-mark

Page 1: ...Industrial Ethernet 5 port Switch www westermo com Westermo Teleindustri AB 2005 User Guide 6644 2230 SDW 550 ...

Page 2: ... 2 Safety 4 5 3 Approvals 5 3 1 Declaration of Conformity 6 4 Specification 7 5 Maintenance 8 6 Installation 8 6 1 Mounting Removal 8 6 2 Connections 9 6 2 1 Power 10 6 2 2 TX 10 6 3 DIP switch settings SDW 550 11 13 6 5 LED indicators 14 ...

Page 3: ...itch The SDW 550 has been designed to meet high industrial specifications providing very high dependability in harsh environmental conditions Features TX shields individually isolated Wide DC power range 12 48 VDC Wide temperature range Automatic MDI MDI X crossover LED indicators for Power Speed Duplex Link and Traffic Port monitoring 35 mm DIN rail mounting Enable or disable of flow control Exam...

Page 4: ...e by double or reinforced insulation Installation This unit should only be installed by qualified personnel This unit should only be installed in a restricted access area for example a lock able cabinet where access is restricted to service personnel only This unit is intended for permanent connection to the DC mains supply The power supply wiring must be sufficiently fused and if necessary must b...

Page 5: ... not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock or shake the unit rough handling above the specification may cause damage to internal circuit boards Do not use harsh chemicals cleaning solvents or strong detergents to clean the unit Do not paint the unit Paint can clog the unit and prevent proper operation Do not expose the unit to any kind of liqu...

Page 6: ...n Herewith declares that the product s Type of product Model Art no Installation manual DIN rail SDW 550 3644 0001 6644 2230 is in conformity with the following EC directive s No Short name 89 336 EEG Electromagnetic Compatibility EMC References of standards applied for this EC declaration of conformity No Title Issue EN 61000 6 2 Immunity for industrial environments 2 2001 EN 61000 6 3 Emission s...

Page 7: ...on TX signal Interface to all other 2 1 kV DC 1 5 kV RMS 50 Hz and 60 s duration TX shield Interface to all other 1 5 kV DC 1 0 kV RMS 50 Hz and 60 s duration Environmental Temperature operating 25 to 70 C Temperature storage and transportation 25 to 70 C Relative humidity operating 5 to 95 non condensing Relative humidity storage and transportation 5 to 95 condensation allowed outside packaging C...

Page 8: ...ng the unit from DC mains supply and all other electrical connections Mounting This unit should be mounted on 35 mm DIN rail which is horizon tally mounted on a wall or cabinet backplate This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Recommended spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit Snap on mo...

Page 9: ...9 6644 2230 6 2 Connections Power connection Network RJ 45 connection Network RJ 45 connection LED indicators Available models SDW 550 10 100Base T TX 5 ports ...

Page 10: ...nection RJ 45 connector automatic MDI MDI X crossover Contact Signal Name Direction Description Remark 1 TD In Out Transmitted Received data 2 TD In Out Transmitted Received data 3 RD In Out Transmitted Received data 4 5 6 RD In Out Transmitted Received data 7 8 Shield HF connected CAT 5 cable is recommended Unshielded UTP or shielded STP connector might be used 8 7 6 5 4 3 2 1 3 pos screw termina...

Page 11: ...en connected equipment Prevent access to hazardous voltages by disconnecting the unit from DC mains supply and all other electrical connections NOTE When configuration via DIP switches the settings of DIP switches configure the unit only after a reboot power off on To be observe when the DIP switches will be configured Speed and duplex setting only valid when auto negotiation is disabled When moni...

Page 12: ... Mbit s speed selected ON 1 2 3 4 5 6 7 8 S1 Half duplex selected ON 1 2 3 4 5 6 7 8 S1 Full duplex selected Port 2 settings ON 1 2 3 4 5 6 7 8 S1 Auto negotiation and auto MDI MDI X disabled ON 1 2 3 4 5 6 7 8 S1 Auto negotiation and auto MDI MDI X enabled ON 1 2 3 4 5 6 7 8 S1 10 Mbit s speed selected ON 1 2 3 4 5 6 7 8 S1 100 Mbit s speed selected ON 1 2 3 4 5 6 7 8 S1 Half duplex selected ON 1...

Page 13: ...1 2 3 4 5 6 7 8 S2 100 Mbit s speed selected ON 1 2 3 4 5 6 7 8 S2 Half duplex selected ON 1 2 3 4 5 6 7 8 S2 Full duplex selected Port mirroring settings ON 1 2 3 4 5 6 7 8 S2 No monitoring selected ON 1 2 3 4 5 6 7 8 S2 Monitoring selected Flow control selected S3 Flow control selected S3 No flow control selected Factory settings ON 1 2 3 4 5 6 7 8 S1 ON 1 2 3 4 5 6 7 8 S2 S3 ON 1 2 3 4 ON 1 2 3...

Page 14: ...ex DPX of TX ports LED Status Indication of PWR ON Internal power initialising OK Slow flash Initialisation progressing Fast flash Initialisation error LINK OFF No Ethernet link ON Good Ethernet link Flash Ethernet data is transmitted or received traffic indication SPD OFF 10 Mbit s TX only ON 100 Mbit s DPX OFF Half duplex TX only ON Full duplex ...

Page 15: ...adsvei 20 0489 Oslo Norway Phone 47 220 903 03 Fax 47 220 903 10 E mail contact ontimenet com Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Communications GmbH Goethestraße 67 68753 Waghäusel Tel 49 0 7254 95400 0 Fax 49 0 7254 95400 9 E Mail info westermo d...

Reviews: