48
6193-3201
General
Expected line-of-sight
range
USA / Canada
Australia / NZ
Range based on 19200
baud
Range may be extended
using intermediate
modules as repeaters.
20+ miles @ 4W ERP
20+ km @ 1W ERP
depending on local
conditions
60+ miles can be achieved in
low RF noise environments
@ 0.1W with 16dB antennas
Note: only 6dB gain is
permitted in USA/Canada
Antenna Connector
Female SMA coaxial
Wireless data rate (bit/
sec) – configurable
19200, 38400, 100000,
200000
“Auto” function determines
fastest rate within user-con-
figured fade-margin
Serial Ports
RS-232 Port
DB9 female DCE
RTS/CTS/DTR/DCD
hardware signals provided
RS-485 Port
2 pin terminal block
Max distance 4000’ / 1.2 km
Data rate (bit/sec)
– configurable
1200, 2400, 4800, 9600,
14400, 19200, 38400,
57600, 76800, 115200
Byte format
7 or 8 data bits
Stop/start/parity bits
configurable
System Parameters
System address
255 word string
Wireless data encryption
None, 64-bit proprietary
or 128-bit AES
User Configuration
Via embedded web page
Via RS-232 commands
Diagnostics
LED’s
OK, DCD,
Radio and Serial RX/TX
Low signal receive led
RSSI measurement in
dBm
BER test