background image

Industrial Converter

PROFIBUS DP to 

Fibre Optic Link.

Point to Point applications

www.westermo.com

©

W

estermo T

eleindustri 

AB 

• 

2005

User Guide

6650-2201

ODW-611

Fibre Optic Modem

Summary of Contents for ODW-611

Page 1: ...Industrial Converter PROFIBUS DP to Fibre Optic Link Point to Point applications www westermo com Westermo Teleindustri AB 2005 User Guide 6650 2201 ODW 611 Fibre Optic Modem...

Page 2: ...cular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Unde...

Page 3: ...ort or any connected fibre although this unit is designed to meet the Class 1 Laser regulations Care recommendations Follow the care recommendations below to maintain full operation of unit and to ful...

Page 4: ...nce No maintenance is required as long as the unit is used as intended within the specified conditions Agency approvals and standards compliance FCC Part 15 105 Notice This equipment has been tested a...

Page 5: ...50 0120 3650 0130 6650 2221 Industrial Converter RS 232 to fibre optic link ODW 622 3650 0601 3650 0610 3650 0620 3650 0630 6650 2231 ODW 631 3650 0201 3650 0210 3650 0220 3650 0230 6650 2221 Industri...

Page 6: ...0 Hz EN 61000 4 16 Signal ports 100 V 50 Hz line to earth Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Voltage dips EN 61000 4 29 DC power ports 10 100 ms interruption and inter...

Page 7: ...way installations The PROFIBUS data rate is set automatically as soon as ODW 611 has identified a correct data frame Retiming ensures the correct PROFIBUS DP signal format 9 position D sub PROFIBUS DP...

Page 8: ...611 has identified a cor rect data frame independently of whether data is received from PROFIBUS DP or the fibre optical link Detected data rate remains until a number of consecutive faulty received...

Page 9: ...tage SELV It is designed to operate permanently over a wide input range and provided with two independent inputs for enhanced redundancy if either supply fails 9 position D sub PROFIBUS DP connector T...

Page 10: ...Bit 1 0 s Signal processing fibre to electrical max 0 3 s 0 3 s Overall system delay one way From received 5 s km 5 s km PROFIBUS DP data at one unit until 1 0 s 1 tBit 1 0 s 5 tBit transmitted data a...

Page 11: ...ion to PROFIBUS DP and Status port Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Power Interface specifications Port type Signal relay changeover contacts Rated voltage Up...

Page 12: ...cal power Maximum min min min min Bit error rate BER 1 x 10 10 1 x 10 10 1 x 10 10 2 5 x 10 10 Transceiver type Small Form Factor Pluggable SFP Multi Sourcing Agreement MSA compliant Laser class Class...

Page 13: ...ibre for details see page 12 Power screw terminal Connections Status screw terminal 3 position Direction Description No 1 NO Contact with C when link is in operation No 2 C Common No 3 NC Open no cont...

Page 14: ...PR Flash Receive data on the electrical PROFIBUS DP port Data will be transmitted to the fibre link if it is a correct PROFIBUS DP frame OFF FR Flash Receive data on the Fibre Link This frame is trans...

Page 15: ...5 tBit interruption in receiving frames until inactive BA2 3 ON 1 2 3 4 5 6 7 8 2 consecutive faulty frames until inactive BA1 ON 1 2 3 4 5 6 7 8 3 consecutive faulty frames until inactive BA1 ON 1 2...

Page 16: ...Spacing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be moun...

Page 17: ...to point application is up and running Hints If the distance is long it may be necessary to adjust the bus parameter Slot time the monitoring time tBit of the sender of frame for acknowledgement of r...

Page 18: ......

Page 19: ......

Page 20: ...89 Oslo Norway Phone 47 22 09 03 03 Fax 47 22 09 03 10 E mail contact ontimenet com Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489...

Reviews: