background image

17

6157-2003

1.  Intruduction

The MD-45 is used to convert between RS-422/485 and RS-232/V.24 signals. This device 
is often used in multidrop applications connected to a PC or PLC. 
    In 2-wire half duplex applications (RS-485) the direction of the bus can be controlled 
by data which means that the converter turns the bus depending on the data sent on the 
bus.  This makes it possible to use the unit with equipment that has no handshaking sig-
nals. The maximum transmission rate possible is 115.2 kbit/s.

CHANNEL 

3

PWR

RD

TD

DCD2

DCD3

DCD4

CHANNEL 2

POWER

LD-01 DC

CHANNEL 

4

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

R+

R-

T+

T-

T+

T-

R+

R-

CHANNEL 

3

PWR

RD

TD

DCD2

DCD3

DCD4

CHANNEL 2

POWER

LD-01 DC

CHANNEL 

4

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

R+

R-

T+

T-

T+

T-

R+

R-

CHANNEL 

3

PWR

RD

TD

DCD2

DCD3

DCD4

CHANNEL 2

POWER

LD-01 DC

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

R+

R-

T+

T-

T+

T-

R+

R-

Summary of Contents for MD-45 AC

Page 1: ...com MD 45 AC MD 45 LV HV Westermo Teleindustri AB Galvanic Insulation Transient Protection Balance d Transmission CE Approved Galvanic Insulation Transient Protection Balance d Transmission CE Approve...

Page 2: ...milj 7 4 4 Mekaniska data 7 5 Underh ll 7 6 Installation 8 6 1 Montering Demontering 8 6 2 Anslutningar 9 6 2 1 Lysdioder 9 6 2 2 Matning MD 45 HV AC 10 6 2 3 Matning MD 45 LV 10 6 2 4 Linjeanslutning...

Page 3: ...r n vilken sida data kommer Det g r det m jligt att ansluta utrustning som ej kan hantera statussignalering MD 45 r avsedd att monteras p en 35 mm DIN skena d r man f ster och l ser modemet med ett en...

Page 4: ...onstruerad f r fast anslutning till AC DC matningsn t och skall install eras av beh rig personal Enhetens anslutning till matningsn tet skall vara tillr ckligt avs krat och om s kr vs skall det vara m...

Page 5: ...ts conforms to the Council Directive 89 336 EEC related to Electro Magnetic Compability and 72 23 EEC Low Voltage Directive Type of equipment DIN rail converter RS232 RS422 485 Model MD 45 AC 3157 010...

Page 6: ...RMS 50 Hz och 60 s varaktighet Linjesp nning MD 45 LV till alla andra 1 0 kV RMS 50 Hz och 60 s varaktighet RS 232 till RS 485 422 1 0 kV RMS 50 Hz och 60 s varaktighet Modellbeteckning MD 45 AC MD 45...

Page 7: ...erande Relativ fuktighet lagring och transport 5 till 95 kondensation p utsidan av f rpackningen till ten 4 4 Mekaniska data Dimension B x H x D 55 x 100 x 128 mm Vikt 0 5 kg AC 0 25 kg HV and LV Mont...

Page 8: ...tningar s att tkomst till farliga sp nningar f rhindras Montering Enheten r avsedd att monteras p en 35 mm DIN skena vilken skall vara horisontellt fastsatt tex p en v gg eller montagepl t i sk p Enhe...

Page 9: ...g Lysdioder Terminalanslutning 9 polig D sub RS 232 6 2 1 Lysdioder PWR Power Indication RTS Request To Send modem signal TD Transmitted Data Displays data received from the local RS 232 422 485 port...

Page 10: ...eanslutning RS 422 485 5 polig skruvplint Riktning Beskrivning Nr 1 In A R Nr 2 In B R Nr 3 In Out A T Nr 4 In Out B T Nr 5 Sk rm 6 2 5 Terminalanslutning RS 232 DCE Skruvplint 9 polig D sub Riktning...

Page 11: ...mna dig till en jordnings punkt tex genom att anv nda handledsband s att skada av intern elektronik p grund av elektrostatiska urladdningar ESD f rhindras innan locket p modemets topp tas av Varning...

Page 12: ...t tri state s ndare ej aktiverad Terminering skall kopplas in p mot tagaren bel gen l ngst bort fr n s ndaren Hj lptabell f r inst llning av antal databitar 7 bitar 8 bitar Ingen paritet Paritet 1 sto...

Page 13: ...kommer in p TD RS 232 S ndaren r sedan aktiv den tid som motsvarar ett tecken plus den s kallade v ndtiden f r inst lld hastighet och antal bitar Om ytterligare data kommer in innan v ndtiden r slut s...

Page 14: ...r att enheten r sp nningssatt RD Indikerar mottagen data p linjesidan CTS Indikerar samma som RTS RTS Indikerar RTS signalen fr n inkopplad utrustning TD Indikerar mottagen data p RS 232 sidan Termine...

Page 15: ...15 6157 2003 ANTECKNINGAR...

Page 16: ...nment 21 4 4 Mechanics 21 5 Maintenance 21 6 Installation 22 6 1 Mounting Removal 22 6 2 Connections 23 6 2 1 LED indicators 23 6 2 2 Power MD 45 HV AC 24 6 2 3 Power MD 45 LV 24 6 2 4 Line connection...

Page 17: ...on the data sent on the bus This makes it possible to use the unit with equipment that has no handshaking sig nals The maximum transmission rate possible is 115 2 kbit s CHANNEL 3 PWR RD TD DCD2 DCD3...

Page 18: ...manent connection to the AC DC mains supply The power supply wiring must be sufficiently fused and if necessary it must be possible to disconnect manually from the AC DC mains supply Ensure compliance...

Page 19: ...ucts conforms to the Council Directive 89 336 EEC related to Electro Magnetic Compability and 72 23 EEC Low Voltage Directive Type of equipment DIN rail converter RS232 RS422 485 Model MD 45 AC 3157 0...

Page 20: ...S 50 Hz and 60 s duration Power MD 45 LV to all other 1 0 kV RMS 50 Hz and 60 s duration RS 232 to RS 485 422 1 0 kV RMS 50 Hz and 60 s duration Model description MD 45 AC MD 45 LV MD 45 HV Rated volt...

Page 21: ...ondensing Relative humidity storage and transportation 5 to 95 condensation allowed outside packaging 4 4 Mechanics Dimension W x H x D 55 x 100 x 128 mm Weight 0 5 kg AC 0 25 kg HV and LV Mounting 35...

Page 22: ...supply and all other electrical connections Mounting This unit should be mounted on 35 mm DIN rail which is horizontally mounted on a wall or cabinet backplate This unit uses convection cooling To avo...

Page 23: ...LED s Terminal connection 9 pos D sub RS 232 6 2 1 LED indicators PWR Power Indication RTS Request To Send modem signal TD Transmitted Data Displays data received from the local RS 232 422 485 port R...

Page 24: ...on screw terminal Direction Description No 1 In A R No 2 In B R No 3 In Out A T No 4 In Out B T No 5 Shield 6 2 5 Terminal connection RS 232 DCE Screw terminal 9 pos D sub Direction Description 7 2 Ou...

Page 25: ...nternal electronics from electrostatic discharges ESD by discharging your body to a grounding point e g use of wrist strap before the lid on top of the modem is removed Warning Do not open connected e...

Page 26: ...Number of bits 9 10 10 10 11 11 11 12 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 No termination Selection of data rate Data or RT...

Page 27: ...he transmitter stays active corresponds to one character time and turning time for the set data rate and number of bits If there is more data on TD before the turning time is ended the transmitter sta...

Page 28: ...it should form a bus structure see diagrams Star shaped networks should never be created there are other Westermo products designed to work in star net applications To get a correct installation accor...

Page 29: ...29 6157 2003 OWN COMMENTS...

Page 30: ...en 35 4 4 Mechanische Daten 35 5 Wartung 35 6 Installation 36 6 1 Installation Deinstallation 36 6 2 Anschl sse 37 38 6 2 1 LED Anzeigen 37 6 2 2 Spannungsversorgung MD 45 HV AC 38 6 2 3 Spannungsvers...

Page 31: ...8 9 R R T T T T R R 31 6157 2003 1 Einleitung Das MD 45 wird zur Wandlung zwischen RS 422 485 und RS 232 V 24 Schnittstellen eingesetzt MD 45 wird oftmals in multidrop Applikationen f r PC und SPS An...

Page 32: ...Versorgungsleitungen sind ausreichend abzusichern und eine manuelle Unterbrechungsm glichkeit ist bei Bedarf vorzusehen Beachten Sie auch die nationalen Vorschriften zu diesem Thema Ein Ger t welches...

Page 33: ...ts conforms to the Council Directive 89 336 EEC related to Electro Magnetic Compability and 72 23 EEC Low Voltage Directive Type of equipment DIN rail converter RS232 RS422 485 Model MD 45 AC 3157 010...

Page 34: ...50 Hz und 60 s Dauer Spannung MD 45 LV zu allen 1 0 kV RMS 50 Hz und 60 s Dauer RS 232 zu RS 422 485 1 0 kV RMS 50 Hz und 60 s Dauer Modelbeschreibung MD 45 AC MD 45 LV MD 45 HV Eingangsspannung 230...

Page 35: ...kondensierend Relative Luftfeuchtigkeit Lager und Transport 5 bis 95 kondensierend au erhalb Verpackung 4 4 Mechanisch Abmessungen BxHxT 55 x 100 x 128 mm Gewicht 0 5 kg AC 0 25 kg HV und LV Montage 3...

Page 36: ...Montage Demontage von allen Spannungsf hrenden Teilen abzuklemmen Montage Das Ger t ist f r die Montage auf einer horizontalen 35 mm Hutschiene vorgesehen Zur K hlung des Ger tes m ssen bestimmte Min...

Page 37: ...6 VDC LED s RS 232 Schnittstelle 9 pol Sub D Buchse 6 2 1 LED Anzeigen PWR Spannungsversorgung TD LED zeigt empfangene Daten an der lokalen RS 232 422 485 Schnittstelle an RD LED zeigt gesendete Daten...

Page 38: ...485 5 pol Schraubklemme Richtung Beschreibung Nr 1 In A R Nr 2 In B R Nr 3 In Out A T Nr 4 In Out B T Nr 5 Schirmung 6 2 5 Terminalanschluss RS 232 DCE Schraubklemme 9 pol Sub D Richtung Beschreibung...

Page 39: ...der Elektronik durch elektrostatische Aufladung ESD indem Sie sich vorher an einem Erdpunkt entladen z B Einsatz eines Erdarmbandes bevor sie den Deckel abnehemen WARNUNG Keine angeschlossenen Ger te...

Page 40: ...er Bits 9 10 10 10 11 11 11 12 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 Keine Termination Einstellung der bertragungsrate Daten...

Page 41: ...am TD RS 232 Eingang aktiviert Die Zeit die der Sender aktiv bleibt h ngt von den Einstellungen f r Umschaltzeit Datenrate und Anzahl der Bits ab Werden an TD weitere Daten gesendet bevor die Umschal...

Page 42: ...werden Siehe Beispiele f r RS 485 2 Draht und RS 422 4 Draht Termination Der Sender des MD 45 wird aktiviert sobald Daten an der RS 232 Schnittstelle empfang en werden nicht wie normale Konverter die...

Page 43: ...43 6157 2003 EIGENE KOMMENTARE...

Page 44: ...49 5 Maintenance 49 6 Installation 50 6 1 Fixation D montage 50 6 2 Connexions 51 6 2 1 Indicateurs de statut LED 51 6 2 2 Alimentation MD 45 HV AC 52 6 2 3 Alimentation MD 45 LV 52 6 2 4 Connexion l...

Page 45: ...e retournement du bus en fonction du sens des donn es qui sont transmises On peut ainsi l utiliser pour connecter des quipements qui ne poss dent pas de gestion par contr le de flux La vitesse maximum...

Page 46: ...ons lectriques adapt es et doit permettre autant que possible de d brancher manuellement l quipement S assurer de la bonne conformit de l installation avec la r glementation nationale en vigueur Tout...

Page 47: ...ucts conforms to the Council Directive 89 336 EEC related to Electro Magnetic Compability and 72 23 EEC Low Voltage Directive Type of equipment DIN rail converter RS232 RS422 485 Model MD 45 AC 3157 0...

Page 48: ...z et durant 60 s Alimentation MD 45 LV vers toutes autres 1 0 kV RMS 50 Hz et durant 60 s RS 232 et RS 485 422 1 0 kV RMS 50 Hz et durant 60 s R f rence Mod le MD 45 AC MD 45 LV MD 45 HV Tension 230 V...

Page 49: ...Humidit relative de transport et stockage 5 95 condensation permise l ext rieur de l emballage 4 4 M caniques Dimensions W x H x D 55 x 100 x 128 mm LxHxP Poids 0 5 Kg AC et 0 25 Kg HV et LV Montage V...

Page 50: ...res connexions pour viter tout risque d lectrocution Fixation Cet quipement doit tre install sur un rail DIN 35mm fix horizontalement sur un mur ou dans une armoire technique Cet quipement utilise une...

Page 51: ...minal Sub D 9 points 6 2 1 Indicateurs de statuts LED PWR T moin d alimentation RTS Signal modem Request To Send TD Transmission de donn es Indique que des donn es sont re ues du port local RS 232 422...

Page 52: ...ction Description N 1 Entr e A R N 2 Entr e B R N 3 Entr e Sortie A T N 4 Entr e Sortie B T N 5 Blindage 52 6157 2003 6 2 2 Alimentation MD 45 HV et AC Bornier vis 3 positions Description L Phase N Ne...

Page 53: ...r f rencez votre corps la terre Par ex utiliser des bracelets antistatiques Afin d viter tout risque de destruction par d charges lectrostatiques OSD des l ments internes Attention Ne pas ouvrir un q...

Page 54: ...s 9 10 10 10 11 11 11 12 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 Pas de terminaison Configuration du d bit des donn es Contr l...

Page 55: ...iode quivalent un caract re temps Et le temps de retournement sera d termin par le format de la transmission vitesse et nombre de bits S il reste des donn es transmettre apr s expiration du temps de r...

Page 56: ...de travailler avec un r seau en toile Une installation correcte d un r seau RS 422 485 doit toujours tre quip e d une terminaison sur les points correspondants Il est indispensable d quiper de termina...

Page 57: ...3 metre Termination Max 32 connections A B A B A B A B A B A B B A A B B A B A B A A B Nota Les d finitions R R T T ne sont pas standard On peut r soudre dans certains cas des probl mes de connexion...

Page 58: ...58 6157 2003 Vos remarques...

Page 59: ......

Page 60: ...tora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com Westermo Teleindustri AB have distributors in several countries contact us for further information Sw...

Reviews: