8

6154-2001

Specifications LD-01

Transmission

Asynchronous, full/half duplex or simplex

Interface 1

EIA RS-232-C/V.24 fixed on channel 1, 
selectable on channel 2 and 3

Interface 2, (W1)

10 mA balanced current loop fixed on channel 4, 
selectable on channel 2 and 3

Connection

Channel 1:

9 pin D-sub female 

Channel 2:

5 pos screw-terminal 

Channel 3, 4:

9 pos screw-terminal

Transmission rate

Data rates up to 38.4 Kbit/s

Indicators

Power 

Channel 1:

RD, TD 

Channel 2–4:

DCD

Isolation

Galvanic isolation with opto-coupler (Interface 2) 
and transformer (supply)
Interface 1 only isolation against supply

Isolation voltage

1500V

Overvoltage protection

Mains: 

Breakdown voltage 430V at 230V AC 

and 230V at 115V AC*
Breakdown voltage transmitter 15V, receiver 5.8V
Surge capacity 0.6 kW during 1 ms

Power supply

115V*/230V AC 48–62Hz +15/–10%

Fuse

100 mA fast 5x20 mm

Power consumption

Max 4VA at 115V*/230V AC

Temperature range

5–50°C, ambient temperature

Humidity

0-95% RH, non-condensing

Dimension

55x100x128 mm (WxHxD)

Weight, kg

AC 0,5 / DC 0,3

Mounting

On DIN-rail 35 mm

* LD-01 115V AC only

Summary of Contents for LD-01 AC

Page 1: ...ungsteiler INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG 6154 2001 www westermo se LD 01 AC LD 01 DC Westermo Teleindustri AB 1999 REV A Galvanic Isolation Transient Protection Ba...

Page 2: ...hannel 1 RD TD Channel 2 4 DCD Isolation Galvanic isolation with opto coupler Interface 2 and transformer supply Interface 1 only isolation against supply Isolation voltage 1500V Overvoltage protectio...

Page 3: ...UNIT Switch settings The LD 01 can through different switch settings be adapted to a variety of running conditions To set the switches open the lid on the top of the plastic case V or Y function Fact...

Page 4: ...ion RS 232 C V 24 Direction Pin configuration 10mA balanced current loop Signal name Channel 2 Channel 3 Channel 4 Receiver 1 9 2 R Receiver 2 8 1 R Transmitter 3 7 4 T Transmitter 4 6 3 T 5 5 5 1 Shi...

Page 5: ...m 4800 5000m 9600 2500m 19200 1000m 38400 500m LD 01 DC Specifications Power supply 12 36V DC 36 55V DC Power consumption Max 3W Insulation 1000V Fuse F1 1 6 A fast 5x20 mm LD 01 DC 36 55V DC only All...

Page 6: ...n a multidrop system The maximum number of units in serial connection is 14 units The drop channel no 1 is configured as DCE Data Communication Equipment Most printers PC s and terminals are set as DT...

Page 7: ...13 6154 2001 OWN COMMENTS...

Page 8: ...tra e 18 68753 Wagh usel Tel 49 0 7254 95400 0 Fax 49 0 7254 95400 9 E Mail westermo germany t online de Westermo Data Communications Ltd Unit 14 Talisman Business Centre Duncan Road Park Gate Southam...

Reviews: