Safety
Before installation:
Read this manual completely and gather all information on the unit. Make sure
that you understand it fully. Check that your application does not exceed the safe
operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is
restricted to service personnel only. The power supply wiring must be sufficiently
fused, and if necessary it must be possible to disconnect manually from all power
supply. Ensure compliance to national installation regulations. This unit relies on
convection heating. Make sure that it is installed so that the ambient temperature
is within the specified temperature range, e.g. by avoiding obstruction of the
airflow around the unit. Also check chapter EN 45545-2 mounting notes.
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from all power supply.
WARNING
Do not open connected unit. Hazardous voltage may occur within this unit when
connected to power supply.
Before powering-up, a protective earthing conductor must be connected to the
protective earthing terminal and have a cross-sectional area of at least 1.5 mm².
Note that this unit can be connected to two different power sources.
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line
cord.
!
!