Westell VirtualEdge VELGX-30 Manual Download Page 3

Section VEL‐GX3‐20A

030‐101804 Rev. B

R

3

1310IARB

Figure 3.  Mounting Views

19” Rack Mounting

23” Flush Rack Mounting

Wall Mounting

Attach long flange of ear to VELGX‐30 panel

Attach panel to rack

D
D

Attach short flange of ear to VELGX‐30 panel

D

Attach panel to rack

D

Attach ears to panel, as shown

D

Mark and pre‐drill mounting holes in wall*

D

(brackets reversed/flipped)

Attach panel to wall 

D

(Use keyhole‐shaped holes)

Panel is flush against front face of channel**

Long flange
of ear attaches
to rack channel

Short flange
of ear attaches
to rack channel

* Can be mounted vertically, if desired.

** For a “projected” appearance, bring or mount the panel further forward on the ears.

D‐rings are optional

D‐rings are optional

(ships with towel bar attached)

1.

Determine vertical position in rack. 

Determine and select

the vertical mounting location in the rack. This panel re­
quires one 

vertical 

Rack Unit (RU) in a standard Telco

relay rack.

2.

Remove ears from bag.

 Locate the bag of parts shipped

with the panel and remove the two L‐shaped mounting
ears and the rack mounting hardware. Each ear flange has
several sets of mounting holes in it.

3.

Determine horizontal position (shelf projection). 

The

mounting ears and the panel's side flanges have several
mounting holes from which to choose, for the desired
amount of projection in the rack. If a

 projected look

 or ori­

entation in the rack is desired, the ears should be attached
in the last, rear‐most, ear hole position on the panel's side
flanges, so that the panel will be projected further forward
from the mounting ears. If a 

flush look

 in the rack is de­

sired, the mounting ears should be attached in the first or
forward‐most ear hole position on the panel's side flanges.

4.

Attach short flange of ear to panel. 

Attach both ears to the

panel in the desired projection position as determined in
the step above, using the hardware provided. The ear's
short flange abuts the panel.

5.

Attach panel to rack. 

Lift the panel and attach it to the rack

channels in the correct vertical rack position. Align the
holes in the ear's long flange with the proper holes in the
rack channels. Insert the provided screws into the aligned
set of  holes, then tighten the  screws. Repeat for both ears.

2.3

Mounting on a Wall

The mounting ears can be attached for wall mounting. Follow
local codes and company practices for the proper wall type.

1.

Determine position on wall. 

Select the mounting location

on the approved wall. This panel requires one 

vertical

Rack Unit (RU) in a standard Telco relay rack. 

Note that the

panel can be mounted in a vertical position, if desired.

2.

Remove ears from bag.

 Locate the bag of parts shipped

with the panel and remove the two L‐shaped mounting
ears and the rack mounting hardware. Each ear flange has
several sets of mounting holes in it.

3.

Determine horizontal position (wall projection). 

The

mounting ears and the panel's side flanges have several
mounting holes from which to choose, for the desired
amount of projection from the wall. If a

 more projected

position 

on the wall is desired (allows greater rear access),

the ears should be attached in the last, rear‐most, ear hole
position on the panel's side flanges. If a 

less projected posi­

tion 

on the wall is desired (allows more front access), the

mounting ears should be attached in the first or forward‐
most ear hole position on the panel's side flanges.

4.

Attach ears to panel. 

Attach both ears to the panel in the

desired projection position as determined in the step
above, using the hardware provided.

5.

Mark mounting hole locations. 

Lift and place the panel on

the wall in the desired final position and mark the mount­
ing holes to be drilled in the wall with a marking utensil.

Summary of Contents for VirtualEdge VELGX-30

Page 1: ...the included re versible mounting ears included in the bag of parts These ears allow flush or projected positions in both 19 and 23 stan dard EIA relay racks or they can be flipped and repositioned at the back of the panel for wall mounting See Part 2 and Figure 3 for more detailed mounting information Figure 1 Isometric View of VELGX 30 Panel Attached ears are shipped loose in a bag of parts Towe...

Page 2: ...nel are provided as well as screws to mount the panel to a rack 2 1 Mounting in a 19 Rack The panel is shipped from the factory pre assembled Each panel includes two L shaped reversible mounting ears lo cated in the bag of parts For 19 rack mounting the mounting ear s short flange attaches to the rack channel 1 Determine vertical position in rack Select the vertical mounting location in the rack T...

Page 3: ...ear to panel Attach both ears to the panel in the desired projection position as determined in the step above using the hardware provided The ear s short flange abuts the panel 5 Attach panel to rack Lift the panel and attach it to the rack channels in the correct vertical rack position Align the holes in the ear s long flange with the proper holes in the rack channels Insert the provided screws i...

Page 4: ...s into their proper or desig nated positions in the provided Keystone type adapter panels 3 Align the two plastic Ny latch fasteners on each side of the cassette or adapter panel with the holes at both sides of the empty LGX type cut out position on the panel In sert the fasteners into the holes and press them until they click snap or lock in place Verify the adapter panel is se curely attached to...

Page 5: ...t the Westell World Wide Web site at http www Westell com 4 2 Part Numbers This equipment is identified by a product number A90 VELGX30 which consists of three parts the issue letter of the equipment A the assembly type 90 and the specific model number VELGX30 Each time a change is made to the product which changes the form fit or function of the product the issue letter is incremented or advanced...

Page 6: ...in Table 3 Part Description A90 VELGX30 VirtualEdger Universal Connection Panel for LGX type fiber cassettes trays and or LGX type fiber panels with 3 LGX sized cut out positions rear cable management tray and lacer bar Rack wall mountable 1 RU high Orderable Options A90 VECMTRAY Cable management tray front projection A90 VECMRING3 Cable management D ring Qty 1 A variety of cables and fiber jumper...

Reviews: