Section 311-580-20B
030-101527 Rev. B
17
0407IBRB
Westell B90-311580
CIRCUIT STATUS
CLEI: T1S1ABTAAA
LVL: -13.0dBdsx
LVL: -13.8dBdsx
FRMG: SF
3115-80
FRMG: SF
SIG: OK
SIG: OK
TO FAC
TO CPE
7.5dB LBO
LVL: -12dBdsx
LVL: -4.0dBdsx
FRMG: SF
FRMG: SF
SIG: OK
Normal Operation
SIG: OK
SELECTIONS
^F) Operate FAC Loopback
^C) Operate CPE Loopback
T) Test Mode Provisioning
^T) Enable Test Mode
Enter selection or <Esc> to go back to main menu
Figure 17. Typical Circuit Status Screen - Normal Operation
Figure 18. Typical Circuit Status Screen - Facility Loopback
X
X
Westell B90-311580
CIRCUIT STATUS
CLEI: T1S1ABTAAA
LVL: -13.0dBdsx
3115-80
LVL: 0.0dBdsx
FRMG: SF
FRMG: UNF/UNK
SIG: OK
SIG: AIS
TO FAC
AIS
TO CPE
0dB LBO
LVL: -0.5dBdsx
LVL: -4.0dBdsx
FRMG: SF
Facility Loopback
FRMG:
SIG: OK
SIG:
SELECTIONS
^C) operate CPE loopback
^D) deactivate loopback
Enter selection or <Esc> to go back to main menu
loopback state as well as the configuration of transmission pa-
rameters and options in the loopback path. Figure 20 shows the
NIU in a single loopback mode when FAC-to-CPE Regenera-
tion is Enabled.
9.2.4.7
Using the <Ctrl><D> keys simultaneously will cause
the NIU to deactivate loopback and return the circuit to normal
operation.
9.2.5
TEST MODE PROVISIONING Menu Screen
The TEST MODE PROVISIONING screen (Figure 21) is used
to configure the unit’s options for the test mode. To reach this
screen from the MAIN menu, type <S> to get into the STATUS
Screen and then type <T>. For each option, the display shows
the CURRENT" configuration as well as a NEW" field that
shows what the option can be changed to. Use <tab> or the ar-
row keys to advance to an option field. Use the <space> bar to
change the available options under the NEW" field.
9.2.5.1
Saving The Changed Options
After configuring the options, press <S> to save the new set-
tings.
Note:
If you enter <Esc> without saving, the system will give
a message asking if you want to save the new settings.
- WARNING -
If the craft terminal is disconnected without saving the changes, the
changes will be lost (unit does not save changes automatically).