Equipment Issue 1
030-101598 Rev. D, August 2010
SectionDBM-A20-001-201
R
E
2010 Westell, Inc. All rights reserved.
*CLEI is a trademark of Telcordia Technologies. Westell
r
is a trademark of Westell, Inc.
1008IARD
Westell
r
DBMA200-01 Single-Position DS3 Mounting
CLEI* Code: NCM2WX0DRA
CONTENTS
PAGE #
1. GENERAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2. APPLICATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3. INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4. TESTING & TROUBLESHOOTING
. . . . . . . . . . . . . .
5. CUSTOMER & TECHNICAL SERVICES
. . . . . . . . .
6. WARRANTY & REPAIRS
. . . . . . . . . . . . . . . . . . . . . . .
7. SPECIFICATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.
GENERAL
1.1
Document Purpose
This document describes the Westell
r
DBMA200-01 Single-
Position DS3 Mounting, shown in Figure 1. See Table 1 for
information concerning other models in the same product fami-
ly.
- NOTE -
Hereafter, the DBMA200-01 Single Position Mounting will be
referred to as the 200-01 Mounting".
1.2
Document Status
Revision B changed the module type from a 200 MECHAN-
ICS
r
to a Slim Mechanics module. Revision C updated the
CPR and bar code. Revision D clarifies the product’s ability to
support a +24Vdc power source.
1.3
Product Purpose and Description
The 200-01 Mounting is a wall mountable, single-position mount-
ing for Slim Mechanics DS3 modules, such as Westell Models
522-XX. The mounting provides an automatic cut-thru feature that
maintains transmission continuity when a module is removed from
its slot. The unit is mounted for front access, utilizing minimal wall
space. Input and output connections to/from the unit are made via
BNC connectors. Power, ground and network connections are lo-
cated inside the assembly behind the removable cover.
Power for the assembly and the unit installed is derived from a
22 to 56Vdc power source (-48V is typical, but +24Vdc also may
be used to power the mounting). See Paragraph 3.4 for connec-
tions. Connections are also provided for a back-up power
source. An Alarm output is provided for external reporting of a
power alarm condition.
Figure 1.
Front View of DBMA200-01L4 Mounting
1.4
Product Mounting
The mounting, along with the appropriate plug-in, provides an
interface between a DS3 facility and customer or network equip-
ment. When installed on a customer premises, the 200-01
Mounting is typically located after a DS3 Multiplexer system, on
the network side of the demarcation point between the network
and Customer Premises Equipment (CPE). The automatic cut-
thru feature allows addition or removal and replacement of
modules while maintaining service continuity.
- NOTE -
Please refer to the appropriate DS3 NIU Technical Practice for
additional application and operational details.
1.5
Product Features
The 200-01 Mounting offers the following features.
S
Single-position chassis for one Slim Mechanics (front
panel is half the width of a standard 400-type mechanics
unit) DS3 NIU or DSX-3 plug-in card
S
Automatic cut-thru on card removal
S
Covered network connections
S
Power alarm contacts