Westell CSI-DSP85-252-C Installation Manual Download Page 1

CSI-DSP85-252-C/P & 
CSI-DSP85I-255-C/P 
 Installation Manual

Summary of Contents for CSI-DSP85-252-C

Page 1: ...CSI DSP85 252 C P CSI DSP85I 255 C P Installation Manual...

Page 2: ...rations 10 Mounting the Digital Repeater 12 Optional Accessories 13 Circuit Operational Description 13 Important Installation Notes 13 Functional Block Diagram 14 Mechanical Specifications 15 AC Power...

Page 3: ...results that may be obtained from the products described herein or the infringement by such products of any proprietary rights of any persons Use or application of such information or state ments is...

Page 4: ...ermine the unit s adaptability to various field applications The following pages describe the Cellular and PCS band plans as well as the convention CSI uses to identify and store the files that make u...

Page 5: ...80 UL 1900 1905 DL 1980 1985 UL 1905 1910 DL 1985 1990 UL 1895 1897 5 DL 1975 1977 5 UL 1897 5 1900 DL 1977 5 1980 UL 1900 1902 5 DL 1980 1982 5 UL 1902 5 1905 DL 1982 5 1985 C8 UL 1870 1877 5 DL 1950...

Page 6: ...ons 7 Note Filter file names will be from six to twelve characters long Each character position in the filter file name is used to define the characteristics of the filter as shown above All frequenci...

Page 7: ...mation LED Indicator Automatic safety precautions are built into the amplifier system In the case of a catastrophic system event a shutdown circuit is incorporated that will disable all emissions shou...

Page 8: ...rial cable because of an unusual connector configuration In the vast majority of cases this information will not be needed Local Communication Interface Ports To allow monitoring and control the repea...

Page 9: ...erwise reduced or eliminated without expensive and possibly prohibitive measures In these cases it may not be practical to use the repeater for providing coverage to these sites Selection of external...

Page 10: ...29 dBm 65 dB 41 5 dBm 80 dB 28 2 dBm 64 dB 40 6 dBm 79 dB 27 4 dBm 63 dB 39 7 dBm 78 dB 26 6 dBm 62 dB 38 8 dBm 77 dB 25 8 dBm 61 dB 37 9 dBm 76 dB 25 dBm 60 dB 37 dBm 75 dB 24 4 dBm 59 dB 36 2 dBm 74...

Page 11: ...kets as shown in the drawing to the right Wall Mounting 19 Relay Rack Mounting Mount the repeater as shown and secure front panel with screws Note the CSI digital repeaters must be supported in the 19...

Page 12: ...r CSI AY 1 85 1 99 10 Battery backup 2 hr Single band Cellular model number CSI AY 806 960 14 1 hour dual band model number CS48 985 600 Inside Omnidirectional Antenna Quad band model number CSI AO 70...

Page 13: ...14 Functional Block Diagram...

Page 14: ...Hz Weight 31 0 lbs 14 1 kg Thermal Management Fan Cooled Surface Coating Powder Coat AC Current 3 2 Amps 120 VAC 1 7 Amps 230 VAC Repeater Size Height 5 25 in 3RU Width 19 00 in Depth 20 00 in Heat Ou...

Page 15: ...GE W CDMA CDMA2000 CDMA RHO 0 98 min CDMA2000 1x EVD0 Spurious Emissions Applicable Documents FCC 13 dBm max Per FCC part 2 22 24 Industry Canada 13 dBm max Propagation Delay 2 5 usec Input VSWR Typ 2...

Page 16: ...17 Mechanical Drawing DONER INDOOR SERVER OUTDOOR ETHERNET USB STATUS 2 STATUS 1 2 1 7 6 3 5...

Page 17: ...a host that has a static IP Select Use the following IP Address and enter the IP Address as follows 192 168 1 x where x any number from 2 to 254 inclusive other than 100 The subnet mask is 255 255 255...

Page 18: ...with software version 2 2 4 or prior only letters numbers and underscores are acceptable nomenclature In units with software version 2 3 0 and up Underscores are not accept able however hyphens are ac...

Page 19: ...layed To change gain settings the user will select the Uplink only or Uplink and downlink radio buttons The user then inputs the gain value desired Gain values from 53 5 dB to 85 0 dB may be selected...

Page 20: ...deselect them before programming To aid the user a clear all button is provided on the PCS band and will deselect all band and sub bands simulta neously Pressing the Program button will complete the s...

Page 21: ...Configuration If the repeater includes a USB modem kit click on Remote Network in the navigation box and the screen below is displayed Highlight the carrier on whose network the repeater and modem wi...

Page 22: ...Contact CSI for updates and instructions The user may clear LED indicators alarms and the Event Log by clicking the Clear Log button System Health Install Upload If required in your market visit the S...

Page 23: ...ters numbers hyphens are the only acceptable nomenclature for the Location field and hyphens may not be used as the first or last character If a reboot of the repeater becomes necessary click on the R...

Page 24: ...Log Configuration E mail Configuration page allows the user to enter up to five E mail addresses to which the repeater can send specified alarm messages when the repeater is connected via ethernet or...

Page 25: ...s not the same as shown in figure 1 a null modem adapter optional as shown in Figure 2 may also be required Figure 1 Figure 2 To end the session exit the browser the user will be automatically logged...

Page 26: ...llowing screen is displayed Select the Serial radio button and press OK as shown below Note It may be necessary in the System Properties section of the control panel using Device Manager to determine...

Page 27: ...nd The user name for changing the PCS band is pcsband The password for both bands is csi1234 After entering the password and pressing return the TMI main menu will appear Note by default the Set Param...

Page 28: ...mple from the Link Configuration menu on the previous page selecting 1 Adjust Gain will display the menu shown below After selecting option 1 downlink the current user gain is displayed and the option...

Page 29: ...tablish a link In other words the IP addresses of both the computer used and the repeater must use the same group of IP address number sets For example the repeater ships with the default IP address o...

Page 30: ...res an independent login To make changes to the cellular band the default user name is cellband The default user name for changing the PCS band is pcsband In the field after the prompt type the user n...

Page 31: ...card to become fully functional contact the service provider In addition an IP address must be obtained and entered into the repeater Once the modem has been installed and activated it can be accessed...

Page 32: ...ayed Select Use the following IP address and enter 192 168 1 2 The subnet mask should automatically populate to 255 255 255 0 Scroll down and highlight Internet Protocol TCP IP and click on the Proper...

Page 33: ...nalyzer will need to be equipped with a whip antenna for this Resolution Bandwidth RBW should be set at 200 kHz for GSM and 1 MHz for CDMA If you cannot select these values the closest available value...

Page 34: ...paid by Buyer The provisions of this warranty shall be appli cable with respect to any product which Seller replaces pursuant to it SELLER MAKES NO WARRANTY EXPRESS OR IMPLIED OTHER THAN AS SPECIFICAL...

Page 35: ...n Interface Ports 9 Local Network 19 Log Configuration 26 M Manual Gain Control 16 Maximum RF input Power 16 Modem Interface 32 Modem Interface Remote Ac cess with login 32 Monitoring Alarms 9 N Noise...

Page 36: ...37 Notes...

Page 37: ...38 Notes...

Page 38: ...39 Notes...

Page 39: ...960 1049 001 rev 002...

Reviews: