background image

 Equipment Issue A

030‐101765 Rev. B, November 2013

Section BXM‐161‐7HE‐20A

R

E

 

2013 Westell, Inc. All rights reserved.  

Westell

r

 is a registered trademark of and Westell Boxer

r

 is a registered trademark of Westell, Inc.

Page 1 of 22

1311IARB

Westell

r

 Boxer

r

 BXM1619‐7HE & BXM1619‐7HEG

Outdoor Cabinets with a ‐48VDC 700W Heat Exchanger

CONTENTS

PAGE #

1. GENERAL

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2. FEATURES 3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3. INSTALLATION

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4. MAINTENANCE

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5. SERVICE & REPAIRS

15

. . . . . . . . . . . . . . . . . . . . . . . .

6. CUSTOMER & TECHNICAL SERVICES

17

. . . . . . . .

7. WARRANTY & RETURNS

17

. . . . . . . . . . . . . . . . . . . . .

8. SPECIFICATIONS

18

. . . . . . . . . . . . . . . . . . . . . . . . . . .

9. APPENDIX A ‐ Product Views

20

. . . . . . . . . . . . . . . . . .

1.

GENERAL

1.1

Document Purpose

This document provides general, installation, and specifica­
tion information for the Westell

r

 Boxer

r

 BXM1619‐7HE and

BXM1619‐7HEG Outdoor Cabinets with Heat Exchangers
(‐7HE model shown in Figure 1). This product is designed to
provide Network equipment protection in outdoor environ­
ments while providing a quick and easy customer hand‐off. The
intended audience for this document is engineering, opera­
tions, and installation personnel of MSO, Telco, and utility
companies. See Table 4 for product ordering information and
available options, as well as information on the companion but
optional battery box or skirt that can be mounted under the
Boxer cabinet.

‐ NOTE ‐

Hereafter, either model may be referred to as the “Boxer‐16” or
“cabinet.” Where differences between models apply, “‐7HE” or
“‐7HEG” will be specified.

‐ NESC/OSHA NOTE ‐

All applicable NESC and OSHA requirements shall be followed
during installation of this product.

1.2

Document Status

Whenever this practice is updated, the reason will be stated in
this paragraph. Revision B adds the ‐7HEG model to the docu­
ment, adds several “G” models to Table 

4, adds the

NESC/OSHA note above, adds the GR‐487 Issue 4 compliant
bullet list feature in Paragraph 1.5 (for the ‐7HEG model), and
updates  Figure 4  and  Figure 6  to  show  the  pin‐in‐hex  screw
locks for the ‐7HEG model.

1.3

Product Purpose and Description

Boxer‐16 is a compact, actively‐cooled, NEMA 4 (and GR‐487
for the ‐7HEG model) outdoor cabinet that can house and pro­
tect a wide range of electronic equipment. Up to 16 vertical

Figure 1.     Isometric Closed View of Boxer‐16 Cabinet

RUs  (28”) of 19‐inch wide internal rack space is available to
house Network equipment such as (but not limited to) multi­
plexers, copper bonding solutions, Ethernet switches and
media converters, xDSL boxes, and DS3 hand‐offs. Protective­
ly mounted on the Boxer front door, separate from the interior
rack space, is a heat exchanger with built‐in fan units.

Boxer‐16 supports rapid equipment installation and wiring
through the use of adjustable and removable 19” rack channels.
An access panel is located at the rear of Boxer‐16 to allow easy
access to the rear of the installed equipment. To ensure easy ac­
cess for input and out cabling, Boxer‐16 includes ample room
below the rack space as well as various sized conduit knock‐outs.

1.4

Product Mounting

The Boxer‐16 cabinet is typically mounted outdoors, above
ground on an H‐frame, a wall, square pedestal or post (minimum
8” wide), or a round pole (from 8” to 20” in diameter). Floor or
concrete pad mounting is supported when used with an optional
Boxer battery box or skirt. All mounting hardware must be capa­
ble of supporting the weight of the Boxer‐16 cabinet plus the
weight of any equipment mounted in it. The Boxer‐16 cabinet is
typically located at the customer premises but can be located
anywhere a compact, weather‐tight, outdoor cabinet is required.

Summary of Contents for Boxer BXM1619-7HE

Page 1: ...ocu ment adds several G models to Table 4 adds the NESC OSHA note above adds the GR 487 Issue 4 compliant bullet list feature in Paragraph 1 5 for the 7HEG model and updates Figure 4 and Figure 6 to s...

Page 2: ...Exchanger removable and replaceable 1 5 Product Features Each Boxer 16 cabinet comes fully assembled pre wired tested and ready for field provided customer equipment installation and includes the foll...

Page 3: ...ns and vents Security is provided via a 2 point latch a tamper proof screw lock and a padlock hasp Side wall lift ears Paragraph 2 1 2 5 are provided for temporary installation lift assistance The bot...

Page 4: ...ed for conve nient access to the rear of equipment mounted inside Boxer 16 The purpose of the access panel is to facilitate equipment ac cess cabling and servicing The panel is secured with six tamper...

Page 5: ...ameter knock outs in the floor of the Boxer 16 cabinet where an option al battery box attaches to the cabinet hole patterns of both units match KNOCK OUT REMOVAL NOTE Always remove knock outs where ho...

Page 6: ...nterior of the cabinet reaches 35 C 95 F and turn off when the internal cabinet temperature cools to 25 C 77 F At the core of the heat ex change system are numerous aluminum fins visible through the c...

Page 7: ...card Two fans are wired to each set of terminals Shaded rows indicate installer connections TEMP ALARM DOOR ALARM and Power Table 2 Controller Card Connectors 2 2 6 AC Duplex GFI Outlets for Installe...

Page 8: ...ectrostatic discharge procedures must be followed to maintain personal and equipment safety Do not store units near magnetic electromagnetic or electrostatic fields Always store or ship units in the o...

Page 9: ...out from either direction per hole size WEIGHT NOTE The Boxer 16 cabinet weighs 80 pounds The weight of the inter nal equipment installed in the Boxer 16 should not exceed 90 pounds The mounting surf...

Page 10: ...mbined weight of the cabinet and the equipment mounted inside the cabinet Westell recommends a minimum cabinet installation height of 30 from the ground 1 Find best wall position Locate the best mount...

Page 11: ...ug 11 Determine next step or close up cabinet and clean the site Repeat Steps 6 8 of Paragraph 3 6 1 to determine the next step or finish the physical cabinet installation 3 6 3 Mounting on a Pole or...

Page 12: ...it BXA PM02 Contents Threaded rod Bracket Washers and Nuts BXA PM03 kit also includes a shelf Figure 18 Boxer Mounted on Pole with Pole Mount Kit Pole Also see the instructions in the optional BXA PM0...

Page 13: ...and gap less suppressors The pedestal shall be capable of accepting 120 240 volts single phase and provide hardware for mounting a power meter However Boxer 16 must only be supplied with 120 volts Fo...

Page 14: ...hole pattern accommodates a wide variety of equipment and mounting bracket hole patterns Always follow company practices and the guidelines below when mounting equipment inside the cabinet 1 Verify th...

Page 15: ...te and verify no equipment tie downs cables or wires will interfere with the closing of the door Clean up the installation site per company practice 3 18 Closing and Locking the Cabinet Upon completio...

Page 16: ...mpartment from the door Make a written note of the length of the old power cord RETURN UNIT NOTE Return the old defective unit to Westell and receive a replace ment new unit see Paragraph 7 2 for deta...

Page 17: ...ensor switch into its mount ing bracket from the rear side so the door sensor button protrudes through the hole for it at the front of the mount ing bracket press or snap it into place 6 Test Verify t...

Page 18: ...optional battery box and pole mounted with the pole mount kit see Table 4 Table 3 Boxer 16 Cabinet Physical Specifications 8 SPECIFICATIONS 8 1 Electrical and Physical Specifications The Westellr Boxe...

Page 19: ...on 48VDC A90 BXSC1619 4H Boxer 20 20 RU 19 wide rack Main Cabinet 400W heat exchanger always on 48VDC A90 BXM2019 4HE 400W heat exchanger temp controlled 24 or 48VDC A90 BXM2019 4HE3 Same as the 4HE...

Page 20: ...0 101765 Rev B R 20 1311IARB Appendix A Product Views Figure 24 Bottom View of Boxer 16 Cabinet Showing Dimensions and Knock outs Mounting lift brackets door and heat exchanger not shown For mounting...

Page 21: ...Section BXM 161 7HE 20A 030 101765 Rev B R 21 1311IARB Figure 25 Front Exterior View of Boxer 16 Cabinet 24 0 33 0 24 5 41 0 39 0 Rear View Panel On...

Page 22: ...Section BXM 161 7HE 20A 030 101765 Rev B R 22 1311IARB Figure 26 Right Side Exterior View of Boxer 16 Cabinet 33 0 18 05 20 60 28 10 41 0...

Reviews: