User manual - English
User-manual-HighLine-v.02
01/2021
54
Produktions-
schalter
Eis-
entnahme-
klappe
Abb. 7.2.1: Darstellung Wanne und Wasserstandssonde
Wasser-
stands-
sonde
Wanne
7.2.1 Cleaning the trough and the water level sensor:
(Also see service video capitel 10. or QR code)
6.
Switch off the machine at the
production
switch
(Position
“Produktion aus/off) and pull the
power plug(see capitel 2.3).
7.
Remove any ice remaining in
the storage container. Ice for
consumption must not come into
contact with the detergen.
8.
Adequately wet a clean sponge
or cloth with WESSAMAT special
cleaner and wipe the vertically
positioned
trough
by
reaching
through
the
storage
container.
Repeat this procedure several times.
Keep wetting the sponge or cloth
with WESSAMAT special cleaner as
required. Allow a few minutes for the
special cleaner to act.
9.
Immerse the sponge or cloth in soap water and wipe the trough in order to neutralise the
special cleaner.
10. Clean the trough with clear water. Use a clean sponge or cloth. In case of persistent
soiling and deposits, this procedure (3.-5.) has to be repeated several times.
8.
Then clean the water level sensor. To do this, clean the three vertical sensors from below
with a normal sponge and thereby remove any limescale deposits
9.
Plug in the socket and put the machine back into operation at the production switch
("Production on / on" position). Then clean the storage container! See the following chapter
IMPORTANT:
Almost all cleaners contain acids which can cause corrosion. Therefore, all parts that
have been treated with cleaner must be rinsed thoroughly.