Automatic sauna splash system, type Sauna Plus 8 Basic
Index: 02
Date modified: 22/02/2022
OI No.: BA DW 010-02 Sauna Plus 8 Basic EN.docx
Page 12 of 36
3.4
Technical data
Sauna Plus 8 Basic
Dimensions and weights:
External dimensions
0.70x0.40x0.23 m; HxWxD
Space requirement
0.90x0.50x0.30 m; HxWxD
Space requirement, including operation and maintenance 2.00x0.60x1.00 m; HxWxD
Empty weight/operating weight
10 kg/15 kg
Connection data
Water inlet
1/2” IG (up to 2.5 l/min)
Splash line outflow
3/8” IG
Oven shower head connection
3/8” IG
Electrical connection
230 VAC/50 Hz, 50 W, safety plug
Fuse F500
2A slow, D8, 3x8
Nominal pressure/operating pressure (flow pressure)
1.5-6 barg/1.5-6 barg
Operating data:
Splash water at 4 barg flow pressure
max. 1200 ml per splash at 100%
Fragrance
max. 24 ml per splash at 100%
Cycle time/pause time
1-90 minutes
Fragrance pump
24 VDC
Solenoid valves
1/4” IG, 230 VAC
Control unit for automatic splash system
230V AC
Medium temperature
5-30°C
Ambient temperature technical room
5-30°C
Humidity technical room
max. 70%
Ventilation (in and out)
Recommended in the technical room
Software version
V 2.1
Hardware version
NT 35-R + HMI
3.5
Transport/storage
Please check the device immediately upon receipt for potential transport damage.
ATTENTION!
The device may be damaged by frost or high temperatures. Avoid exposure to frost
during transport and storage! Do not store systems and devices next to objects with
strong heat emission or in direct sunlight. The device may only be transported and
stored in its original packaging. Please ensure careful handling.
For transport and storage purposes, the roller carrier of the dosing pump is not mounted. This prevents
the hose from becoming deformed.
Storage of fragrances/chemicals
DANGER!
The safety data sheets provided by the fragrance manufacturer must be observed dur-
ing storage!
These are some of the points that must be observed:
The fragrances must only be stored in the appropriately identified original plastic containers.
Larger quantities of fragrances must be stored in a separate storage room.
The ambient temperature must not exceed 20°C.
See also Chapter 2.2.1 Handling of chemicals.
ATTENTION!
Pay attention to the locally applicable regulations for handling chemicals!