GRANUDOS 45/100 PLUS V70 Touch
Index: 03
Change date: 25.04.2018
Operating instructions no.: BA SW 001-03 Granudos 45-100 PL V70T.docx
Page 35 of 92
5.
Place the hose holder into the guide inside
the housing until it clicks in. Thereafter,
replace the lock washer and the transparent
pump cover. The roller carrier installation is
then completed.
Proceed in reverse order to de-install the roller carrier and the hose holder.
5.2.2
Prepare acid dosing for operation
The specifications in the safety data sheets for the respective
chemicals must be adhered to, e.g. protective clothing:
Personal protective clothing must be put on before starting work
with chemical substances: Protective gloves, apron, face protection,
boots.
Connect the acid canister:
Poisonous fumes may be created when handling acids. Do not inhale fumes.
1.
Unscrew the screw lid with acid lance from the empty acid canister, place the
suction lance into the collecting tray, and immediately close the empty canister
with the original screw lid.
2.
Lift the empty canister out of the collecting tray.
3.
Place a full acid canister into the collecting tray.
4.
Unscrew the screw lid from the full acid canister and immediately insert the
suction lance of the GRANUDOS PLUS dosing system and screw it tight.
5.
Keep the original screw lid of the acid canister until the next acid change.
5.2.3
Placing the drum / drum change
PROTECTIVE CLOTHING !
Personal protective clothing must be put on before the work is
started: Tightly fitting protective goggles, protective gloves, apron,
face protection, boots
The safety data sheets for the respective chemicals must be adhered
to.
Figure 26, Click in the hose holder