Project Engineering
92
Effective resolution without construction around the sides of the hidden object
• If no mechanical construction is installed in the hidden area, the effective resolution changes according to
the maximum object size.
1
moving
object
Resolution (data sheet)
Relevant hiding (tolerance)
Effective resolution
14 mm
1 beam
24 mm
2
34 mm
3
44 mm
4
54 mm
5
64 mm
6
74 mm
7
84 mm
8
94 mm
30 mm
1 beam
50 mm
2
70 mm
3
90 mm
4
110 mm