Parameters Configuration
152
9.5.3 Parameter Data
NOTE!
• To prevent impermissible or unintentional changes to the ESPE, a password must be
entered to carry out a parameter configuration (see
• Setting parameter data requires user level “Admin”.
• There is only one password for the ESPE, regardless of whether the setting takes place on
the control panel or via IO-Link.
The following parameters can be set and/or read:
Device settings
Block device access
Block parameter settings via IO-Link (regardless of the password)
PasswordParamEntry 4-digit password must be entered to start the parameter configuration
ParamEnd
This parameter must be set and saved to apply the parameter in the memory of the
ESPE
PasswordChange
Change the password
Ident
Information on the parameter set of the ESPE
Basic settings
Operation Mode
Full resolution, reduced resolution, fix blanking (with/without tolerance), floating
blanking
Function Mode
Beam coding, RES, EDM, cascading
Muting Settings
Selection of the muting type and setting of the muting parameters
Display settings
Display.Mode
Standard or energy saving mode
Display-Advanced-
Screen
The current display on the 4-digit segment display on the receiver is shown
Expert settings
SignalOutput
Parameter configuration of the signal output function with inactive IO-Link
communication
Lamp
Parameter configuration of the indicator lamp function
AdjustSignal
Display the signal strength
0 – no synchronization
1 … 4 – signal strength level
FactoryReset
Reset to default settings
SD-Card
Save or load from the microSD card
IO-Link process data
Choose from parameter set A or B (process data)
Beam settings
Beam.Mode
Parametrized safety field status (saved in ESPE)
Beam.State
Current safety field status
Diagnosis
ErrorCode