Safety Light Curtain
143
d) Floating blanking
OSSD
RES
SIG LOW
ERROR
Teach-in
• The parameter configuration takes place by teaching in the
blanking objects. These obstructions must be brought into the
safety field during the teach-in process.
• Pressing the
-key teaches in the highest value recorded
during the teach-in process.
• The values “T999” and “T000” are invalid (e.g.: synchronization
beams blocked).
• The teach value (display TXYY) shows:
– x: number of blocked objects
– yy: the maximum tolerance
– e.g. T102
1 object, 2 beam tolerance.
• The value for the tolerance must be used for calculating the effec-
tive resolution and the safety clearance.
• For more information on the “floating blanking” function, see
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
9.4.10 Setting the Display (DISP)
• The display can be operated in either standard mode or energy saving mode.
• The setting is carried out in the following steps:
Search DISP
Selection
Standard mode
OSSD
RES
SIG LOW
ERROR
Selection
OSSD
RES
SIG LOW
ERROR
Energy saving mode
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
Level 0
Level 1
1. Acknowledge the DISP mode by pressing the
key
2. Choose from “STD”, “ENRG” and “<---” using the
or
key.
The parameters to be selected are shown flashing.
3. Acknowledge the selection by pressing the
key.
4. A selected parameter is displayed for approx. 2 s, before the display switches to the next level (level 2).