Safety Light Curtain
141
9.4.9 Parametrization Blanking (BLNK)
• For general information on the blanking function, see
.
• The following steps are used for activation or deactivation:
Search BLNK
Selection
Switch off
OSSD
RES
SIG LOW
ERROR
Selection
Teach-in
OSSD
RES
SIG LOW
ERROR
Reduced resolution
OSSD
RES
SIG LOW
ERROR
OSSD
RES
SIG LOW
ERROR
Fix blanking
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
Fix blanking with
edge tolerance
OSSD
RES
SIG LOW
ERROR
Floating blanking
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
Level 0
Level 1
1. Acknowledge the BLNK mode by pressing the
key
2. Choose from “OFF”, “REDU”, “FIX”, “FIXT”, “FLB” and “<---” using the
or
key. The parameters to
be selected are shown flashing.
3. Acknowledge the selection by pressing the
key.
4. A selected parameter is displayed for approx. 2 s, before the display switches to the next level
(level 2).
Exception:
If blanking is deactivated (OFF), the display switched back to level 0.
5. In the following level (level 2), the object(s) are taught-in or the display switches back.
NOTE!
The blanking function is only available on the devices SEFG411-SEFG442.