Safety Light Curtain
121
Muting end through clearing of
the ESPE
Off
Partial muting
Off
Full Muting Enable
Off
Gap suppression
Off
Override
Off
Display and expert menu:
Display
Energy saving mode
Signal output
Acknowledgment prompt restart inhibit
Indicator lamp
All (muting and OSSD status)
Password protection
active, 0000
9.4.2 Calling up the Menu (User Level “Admin”)
• The configuration menu can be called up from the RUN mode, as well as from error mode.
• To prevent unintentional parameter configurations, the call-up of the configuration menu is divided into the
following steps:
1. Press and hold the “Menu down” key (
) until the red “ERROR” LED goes out. (approx. 2 s)
2. Release the key and wait until the red “ERROR” LED lights up again. (approx. 2 s)
3. As soon as the red “ERROR” LED lights up, press and hold the “Menu down” key (
) again until the red
“ERROR” LED goes out. (approx. 2 s)
4. Once the button is released, the user is taken to the password menu (PASS).
ERROR
SIG LOW
RES
OSSD
Figure 37: Timing diagram receiver for calling up the menu