Parameters Configuration
118
9.3.1 Default Settings
Function
Default settings
Beam coding
Coding OFF
Range
High range
9.3.2 Calling up the Menu (User Level “Admin”)
• The configuration menu can be called up from the RUN mode, as well as from error mode.
• To prevent unintentional parameter configurations, the call-up of the configuration menu is divided into the
following steps:
1. Press and hold the “Menu down” key (
) until the red “ERROR” LED goes out. (approx. 2 s)
2. Release the key and wait until the red “ERROR” LED lights up again. (approx. 2 s)
3. As soon as the red “ERROR” LED lights up, press and hold the “Menu down” key (
) again until the red
“ERROR” LED goes out. (approx. 2 s)
4. Once the button is released, the settings will be called up (see
CODE
HI RAN
POWER
ERROR
Figure 36: Timing diagram emitter for calling up the menu