10
Technical Data
3.3 Working Range
The sensor’s working range is influenced by two parameters:
• Object remission
• Ambient light
The following values can typically be reached in Precision mode (default):
Ambient Light
Remission
100 lux
5,000 lux
20,000 lux
100,000 lux
White (90 % remission)
50…10,000 mm
50…10,000 mm
50…10,000 mm
50…10,000 mm
Gray (18 % remission)
50…10,000 mm
50…10,000 mm
50…10,000 mm
50…5,000 mm
Black (6 % remission)
50…8,000 mm
50…6,500 mm
50…5,500 mm
50…3,000 mm
3.4 Mode-Dependent Data
Some technical data depend on the mode set. Depending on the setting, the following data are obtained:
P2PY101, P2PY103, P2PY105, P2PY106
Mode
White Work-
ing Range
(90%
Remission)
Gray Working
Range
(18%
Remission)
Black Work-
ing Range
(6%
Remission)
Switching
Frequency
Response
Time
Maximum
Repro-
ducibility
Linearity
Deviation
Low Signal
Detection
Speed
0 – 10,000
mm
0 – 9,000
mm
0 – 7,000
mm
250 Hz
4,7 ms
5 mm
15 mm
+
Precision
(default)
0 – 10,000
mm
0 – 10,000
mm
0 – 8,000
mm
50 Hz
15 ms
3 mm
10 mm
++
Precision
Plus
0 – 10,000
mm
0 – 10,000
mm
0 – 8,000
mm
25 Hz
28,7 ms
3 mm
10 mm
+++
P2PY107, P2PY108
Mode
White Work-
ing Range
(90%
Remission)
Gray Work-
ing Range
(18%
Remission)
Black Work-
ing Range
(6%
Remission)
Measuring
Rate
Maximum
Reproduc-
ibility
Linearity
Deviation
Low Signal
Detection
Speed
0 – 10,000
mm
0 – 9,000
mm
0 – 7,000
mm 500/s
5
mm
15
mm
+
Precision
(default)
0 – 10,000
mm
0 – 10,000
mm
0 – 8,000
mm 100/s
3
mm
10
mm
++
Precision
Plus
0 – 10,000
mm
0 – 10,000
mm
0 – 8,000
mm 50/s
3
mm
10
mm
+++