background image

Operating Instructions

EN

Translation of the Original Operating Instruction  

Subject to change without notice

Available as PDF version only

Version: 1.2.0

Status: 28.01.2019

www.wenglor.com

P1KY10x

High-Performance Distance Sensors

Summary of Contents for P1KY10 Series

Page 1: ...tructions EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 2 0 Status 28 01 2019 www wenglor com P1KY10x High Performance Distance Sensors ...

Page 2: ...3 1 Spot diameter 8 3 2 Switching Distance Deviation 8 3 3 Accessory Products 8 3 4 Layout 9 3 5 Control Panel 10 3 6 Scope of Delivery 10 4 Transport and Storage 10 4 1 Transport 10 4 2 Storage 10 5 Installation and Electrical Connection 11 5 1 Installation 11 5 2 Electrical Connection 11 5 3 Diagnostics 12 6 Settings 14 7 Settings via IO Link 15 7 1 Background Teach In 15 7 2 Window Teach In 15 ...

Page 3: ...means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in accordance with the following principle Attention Getting Word Type and Source of Danger Possible consequences in the event that the hazard is disregarded Measures for averting the hazard The meanings of th...

Page 4: ...pproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product characteristics wenglor assumes no liability for printing errors or other inaccuracies contained in these operating instruc tions unless wenglor was verifiably aware of such errors at the point in time at w...

Page 5: ...als industry Plastics industry Woodworking industry Consumer goods industry Paper industry Electronics industry Glass industry Steel industry Aviation industry Chemicals industry Alternative energy Raw materials extraction 2 2 Use for Other than the Intended Purpose Not a safety component in accordance with 2006 42 EC Machinery Directive The product is not suitable for use in potentially explosive...

Page 6: ...he guarantee may be rendered null and void Modification of the product is impermissible 2 5 General Safety Precautions NOTE These instructions are an integral part of the product and must be kept on hand for the entire duration of its service life In the event of possible changes the respectively current version of the operating instruc tions can be accessed at www wenglor com in the product s dow...

Page 7: ... C Number of switching outputs 2 Switching output voltage drop 2 5 V Switching output switching current 100 mA Short circuit protection yes Reverse polarity protected yes Overload proof yes Interface IO Link IO Link version 1 1 Protection class III Mechanical Data Setting method Teach in Housing material Plastic Lens cover PMMA Degree of protection IP67 IP68 Technical Safety Data MTTFd EN ISO 1384...

Page 8: ...Y1 Typical characteristic curve based on Kodak white 90 remission Sr switching distance dSr change in switching distance Black 6 remission Gray 18 remission 3 3 Accessory Products wenglor can provide you with suitable connection technology for your product Suitable mounting technology no 400 Suitable connection technology no 7 2 S02 PNP NPN converter BG7V1P N 2M IO Link master wTeach2 software DNN...

Page 9: ...9 High Performance Distance Sensors 3 4 Layout P1KY101 P1KY103 P1KY102 P1KY104 1 receiver diode 2 emitter diode M3 screw 0 5 Nm Dimensions specified in mm 1 mm 0 03937 ...

Page 10: ... case of damage con ditionally accept the package and notify the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following points must be taken into condition with regard to storage Do not store the product outdoors Store the product in a dry dust free place Protect the product against mechanical impacts Protect the product against exposure t...

Page 11: ...Specified torque values must be complied with see section 3 Technical Data page 7 ATTENTION Risk of property damage in case of improper installation The product may be damaged Installation instructions must be complied with CAUTION Risk of personal injury or property damage during installation Personal injury and damage to the product may occur A safe installation environment must be assured 5 2 E...

Page 12: ... Warning blinking LED Display LED Diagnosis Cause Elimination Continuous blinking at approx 2 5 Hz Contamination Carefully clean the optic cover with a cloth Aged emitter diode Replace the sensor Unreliable working range Increase the sensor s switching distance Reduce distance between sensor and object Continuous blinking at approx 5 Hz Short circuit Check electrical wiring and eliminate the short...

Page 13: ...ject off off on off off off off blinking off Required action in case of fault NOTE Shut down the machine Analyze and eliminate the cause of error with the help of the diagnostics information If the error cannot be eliminated please contact wenglor s support department Do not operate in case of indeterminate malfunctioning The machine must be shut down if the error cannot be unequivocally clarified...

Page 14: ...ch in key after 2 seconds 5 The distance is taught in and the LED at output 1 lights up in order to confirm successful teach in Foreground Teach In for Switching Output 2 1 Mount the sensor in accordance with the mounting instructions 2 Position the object in front of the sensor 3 Press and hold the teach in key until switching status indicator LED A2 starts blinking 4 Release the teach in key aft...

Page 15: ...ocated between the background and the sensor Object Switching Point Sensor Teach Distance 7 2 Window Teach In Additionally there s also a window teach in option for both outputs 1 Enter or teach in the far switching point 2 If necessary adjust the window with the near and far switching points 3 The sensor is switched when an object is located between the two switching points Object Sensor Teach in...

Page 16: ...rotected against inadvertent changes caused by the teach in key 7 4 External Teach In Teach in output A1 via the teach in input 1 Set the A2 pin function to external teach in 2 Apply 24 V to pin A2 for at least 1 second but for no more than 4 seconds 3 As soon as voltage drops at the input A1 is taught in 7 5 Error Output The error output is switched in the following cases Signal from object too w...

Page 17: ...ce free Cleaning and inspection of the plug connections at regular intervals are advisable Do not clean the sensor with solvents or cleansers which could damage the product The product must be protected against contamination during initial start up 10 Proper Disposal wenglor sensoric GmbH does not accept the return of unusable or irreparable products Respectively valid national waste disposal regu...

Page 18: ...dex Operating Instructions Version Date Description Change 1 0 0 29 06 17 Initial version of the operating instructions 1 1 0 18 12 17 see section 7 Settings via IO Link page 15 1 2 0 15 01 19 New versions added see section 3 Technical Data page 7 11 3 EU Declaration of Conformity The EU declaration of conformity can be found on our website at www wenglor com in the product s down load area ...