Wenglor P1KL Series Operating Instructions Manual Download Page 1

Operating Instructions

EN

Translation of the Original Operating Instruction  

Subject to change without notice

Available as PDF version only

Version: 1.4.0

Status: 22.02.2021

www.wenglor.com

P1KLxxx

Retro-Reflex Sensor 

Summary of Contents for P1KL Series

Page 1: ...ing Instructions EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 4 0 Status 22 02 2021 www wenglor com P1KLxxx Retro Reflex Sensor ...

Page 2: ...nd protection class 6 3 Technical Data 7 3 1 Technical Data 7 3 1 1 Spot diameter 9 3 1 2 Smallest detectable part 9 3 1 3 Switching distance 10 3 2 Complementary Products 11 3 3 Layout 11 3 4 Control Panel 12 3 5 Scope of Delivery 12 4 Transport and Storage 13 4 1 Transport 13 4 2 Storage 13 5 Installation and Electrical Connection 13 5 1 Installation 13 5 2 Electrical Connection 14 5 3 Diagnosti...

Page 3: ...f symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in accordance with the following principle Attention Getting Word Type and Source of Danger Possible consequences in the event that the hazard is disregarded Measures for averting the hazard The meanings of the atten...

Page 4: ...approved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product characteristics wenglor assumes no liability for printing errors or other inaccuracies contained in these operating instructions unless wenglor was verifiably aware of such errors at the point in time at w...

Page 5: ...ceuticals industry Plastics industry Woodworking industry Consumer goods industry Paper industry Electronics industry Glass industry Steel industry Aviation industry Chemicals industry Alternative energy Raw materials extraction 2 2 Use for Other than the Intended Purpose Not a safety component in accordance with 2006 42 EC Machinery Directive The product is not suitable for use in potentially exp...

Page 6: ...the guarantee may be rendered null and void Modification of the product is impermissible 2 5 General Safety Precautions NOTE These instructions are an integral part of the product and must be kept on hand for the entire duration of its service life In the event of possible changes the respectively current version of the operating instructions can be accessed at www wenglor com in the product s dow...

Page 7: ...8 30 V DC Temperature drift 10 Temperature range 40 60 C Switching output voltage drop 2 V Switching output switching current 100 mA Switching output residual current 50 µA Short circuit protection Yes Reverse polarity protected Yes Overload proof Yes Lockable Yes Interface IO Link IO Link version 1 1 Protection class III Mechanical Data Setting method Potentiometer Housing material Plastic Degree...

Page 8: ... cm 100 cm Connection Diagram No 214 212 215 215 213 216 171 217 213 218 1014 Suitable Mounting Technology No 7 2 2 8 8 8 7 8 2 Order Number Technical Data P1KL 006 027 014 007 015 008 016 017 018 019 021 Range 12000 mm 3000 mm Light Source Laser red Opening Angle 0 1 Switching hysteresis 15 Laser Class EN 60825 1 1 Spot Diameter see Table 2 0 5 mm Smallest detectable part see Table 4 0 15 mm Curr...

Page 9: ...0 mm Table 1 Range 0 2 m 5 0 m 12 0 m Spot diameter 4 mm 11 mm 22 mm Table 2 3 1 2 Smallest detectable part Distance sensor reflector 0 2 m 2 0 m 5 0 m Smallest detectable part 10 mm 20 mm 30 mm Table 3 Distance sensor reflector 2 m 4 m 12 0 m Smallest detectable part 1 5 mm 1 0 mm 2 5 mm Table 4 ...

Page 10: ... 01 3 00 m 0 10 16 00 m 0 4 3 m RE6040BA 0 01 3 50 m 0 10 15 00 m 0 4 3 m RE8222BA 0 01 2 50 m 0 10 10 00 m 0 4 3 m RR34_M 0 01 0 60 m 0 10 2 50 m 0 35 3 m RE3220BM 0 01 1 50 m 0 10 7 00 m 0 35 2 m RE6210BM 0 01 1 50 m 0 10 4 50 m 0 35 1 9 m RR25_M 0 01 1 30 m 0 10 7 00 m 0 35 2 2 m RR25KP 0 01 0 80 m 0 10 2 50 m 0 35 0 9 m RR21_M 0 01 1 10 m 0 10 7 00 m 0 35 2 m ZRAE02B01 0 01 2 00 m 0 10 7 00 m ...

Page 11: ...r product Suitable mounting technology no 400 Suitable connection technology no 7 2 S02 8 S04 PNP NPN converter BG7V1P N 2M IO Link master wTeach2 software DNNF005 3 3 Layout P1KL002 P1KL004 P1KL005 P1KL006 P1KL007 P1KL008 P1KL009 P1KL010 P1KL013 P1KL014 P1KL015 P1KL016 P1KL017 P1KL018 P1KL019 P1KL021 P1KL001 P1KL011 ...

Page 12: ... screw 0 5 Nm Potentiometer 40 Nmm Dimensions specified in mm 1 mm 0 03937 3 4 Control Panel 68 05 1K1 30 05 switching distance adjuster 30 switching status indicator contamination warning 68 supply power indicator 3 5 Scope of Delivery Sensor Safety precautions Mounting Set 01 ...

Page 13: ...improper storage The product may be damaged Storage instructions must be complied with 5 Installation and Electrical Connection 5 1 Installation Protect the product from contamination during installation Observe all applicable electrical and mechanical regulations standards and safety rules Protect the product against mechanical influences Make sure that the sensor is mounted in a mechanically sec...

Page 14: ...n Blue Violet Grey White Pink Green Yellow Supply Voltage Supply Voltage 0 V Supply Voltage AC Voltage Switching Output NO Switching Output NC Contamination Error Output NO Contamination Error Output NC Input analog or digital Teach Input Time Delay activation Shielding Interface Receive Path Interface Send Path Ready Ground Clock Output Input programmable Power over Ethernet Safety Input Safety O...

Page 15: ...ature Disconnect the sensor from supply power and allow it to cool down Hardware error Replace the sensor Contamination Warning Flowcharts not detected not detected detected beginning contamination not detected not detected detected Retro Reflective Barrier no contamination Object Switching Status Indicator Object Switching Status Indicator Object Switching Status Indicator not detected not detect...

Page 16: ...ge in case of non compliance The system s safety function is disabled Personal injury and damage to equipment Required action as specified in case of fault 6 Settings Align the sensor to the reflector Make sure that the sensor and the reflector are mounted in a mechanically secure fashion Turn the potentiometer all the way to the right Turn the potentiometer back if required detection of small or ...

Page 17: ...aste disposal regulations apply to product disposal 10 Appendix 10 1 List of Abbreviations Abbreviation Meaning Tu Ambient temperature Ub Supply voltage IODD IO Device Description MTTFd Mean Time to Dangerous Failure 10 2 Change Index Operating Instructions Version Date Description Change 1 0 0 11 05 17 Initial version of the operating instructions 1 1 0 05 12 17 3 Technical Data on page 7 1 2 0 1...