![Wenglor P1HJ1 Series Operating Instructions Manual Download Page 12](http://html1.mh-extra.com/html/wenglor/p1hj1-series/p1hj1-series_operating-instructions-manual_956837012.webp)
12
Installation and Electrical Connection
5.3 Diagnostics
Causes for Triggering the Contamination Warning (blinking LED):
Display LED
Diagnosis/Cause
Elimination
Continuous blinking
at approx. 2.5 Hz
Contamination
Carefully clean the optic cover with a cloth.
Aged emitter diode
Replace the sensor.
Unreliable working range
• Increase the sensor’s switching distance.
• Reduce distance between sensor and object.
Continuous blinking
at approx. 5 Hz
Short-circuit
Check electrical wiring and eliminate the short-circuit.
Over-temperature
Disconnect the sensor from supply power
and allow it to cool down.
Hardware error
Replace the sensor.
Contamination Warning Flowcharts