13
6.1. Run
Sensor switches to display mode.
Order number
Current measured value in mm
Bar graph display of the current
measured value relative to the
measuring range
Status LEDs
Symbol descriptions of status LEDs:
Symbol
Significance
State 1
State 2
State 3
Symbol 1
Warm-up
ok
wait
–
Symbol 2
Signal Strength
ok
too low
(dirty)
too high
Symbol 3
Temperature
ok
too high
too low
6.2. Display
Display
Adjust the display device
Mode
Rotate
Intensity
3
Back
7
Run
Mode:
Select display mode (see chapter 7.2.1)
Rotate:
Rotate display by 180°. By pressing the “
” button the display is rotated
by 180°. The rotation is canceled by pressing this button again.
Intensity:
Set the display intensity (see chapter 7.2.2)
6.2.1. Display Mode
The sensor display always shows the measured value in mm and the oder number. In the menu item “Display
mode” the following additional displays can be selected:
Mode
Adjust the display device
Process
Text
Analysis
Network
Process:
Display of status LEDs for warm-up, signal strength, and temperature.
Text:
Display of a free text which can be sent to the sensor via the controller.
Analysis:
Display of signal strength in percent and measurement rate in 1/s.
Network:
Display of EtherNet/IP
TM
-LED's, NS, MS, and L/A. For the function of these