15
Sensors for Roller Conveyor Systems
The sensor can be removed by pressing gently with a screwdriver at the top in order to release the
mechanism and then pulling the sensor out to the front (C). The retaining plate can be removed by
unscrewing the percussion rivets with a screwdriver (D).
Optionally, the retaining plate can be attached to the conveyor using M5 screws. The drill-hole pattern
corresponds to the ZPTX002. The screws are not included in the scope of delivery.
If the ZPTX003 quick mounting system is used, no mounting holes are provided in the retaining plate.
These must be individually positioned in accordance with the installation situation. A suitable drill or
stamping tool must be used to this end. The method used to mount the retaining plate to the conveyor must
be selected individually as well. The percussion rivets included with the ZPTX001 quick mounting system
can be ordered separately under order number ZPTE001 if required.
5.1.2 Installation with ZPTX002 Mounting Bracket
The sensor is attached to the bracket with two M4 screws. The screws, washers and nuts are included
with the ZPTX002. The sensor can be adjusted (tilted back by up to 5.5°) until the screws are tightened.
The bracket is mounted to the conveyor with two M5 screws. The mounting holes in the bracket are
pre-threaded. The M5 screws are not included in the scope of delivery and must be selected in accordance
with the installation situation.
→↔↓↕
M5 thread for individual
mounting with M5 screws
Screws, washer,
nuts M4
5,5 °