14
EN
7.5. Industrial Ethernet Cable with Power over Ethernet
To ensure cabling as simple and reliable as possible, we recommend using our preassembled industrial Ether-
net cables. In addition, several branches can be connected. The PoE ports (x2 – x6) can also be used for this
purpose. Please note that the next branch must always be operated via the EtherCAT in port (x1). ZAT50NN01
field-assembly connectors see chapter “4.3. Supplementary products” on page 7) must be used for these con-
nections.
Assignment of the Industrial Ethernet connection with PoE:
1
2
3
4
5
6
8
7
Pin
Function
1
TxD (+)
2
TxD (–)
3
RxD (+)
4
RxD(–)
5
PoE (+)
6
PoE (+)
7
PoE (–)
8
PoE (–)
7.6. Connecting Digital Sensors and Actuators
1
2
3
4
Pin
Function
1
24 V
2
Freely programmable
input/output
3
0 V
4
Freely programmable
input/output
Sockets that are not used must be provided with caps, which are included in the scope of supply. Otherwise,