Wenger Diva 185E549 User Instructions Download Page 1

User Instructions

Diva

®

 Air Transporter

©Wenger Corporation 2021 

Printed in USA 2021-08 

Part #185A462-02

Wenger Corporation,

 555 Park Drive, P.O. Box 448, Owatonna, Minnesota 55060-0448

Questions? Call.....USA: (800) 4WENGER (493-6437) • Worldwide: +1-507-455-4100 • wengercorp.com

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

General  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Manufacturer  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

European Representative  . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Name and Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Machine Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

EC Declaration of Conformity  . . . . . . . . . . . . . . . . . . . . . . . . 3

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Stage Load Specifications

  . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Floor Level Specifications

  . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Required Working Environment   . . . . . . . . . . . . . . . . . . . . . . 5

Main Electrical Power Supply  . . . . . . . . . . . . . . . . . . . . . . . . 5

Ground Connection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Ambient Light Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Control Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Tower Set Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Power Failure   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Abnormal Uses  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Air Beam Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Check Size of the Air Beam   . . . . . . . . . . . . . . . . . . . . . . . . . 12

Remove Current Air Beam   . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Attach New Air Beam   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Contents

Note:

  Please read and understand these instructions before using.

Note:

  If you need additional information, contact Wenger Corporation using the information below.

Visit the Diva Acoustical Shell web page at wengercorp.com for more information.

Summary of Contents for Diva 185E549

Page 1: ...ns 4 Stage Load Specifications 5 Floor Level Specifications 5 Required Working Environment 5 Main Electrical Power Supply 5 Ground Connection 5 Operation 6 Ambient Light Levels 6 Control Devices 6 Tower Set Up 7 Power Failure 11 Abnormal Uses 11 Replacement Parts 11 Training 11 Air Beam Replacement 12 Check Size of the Air Beam 12 Remove Current Air Beam 13 Attach New Air Beam 15 Contents Note Ple...

Page 2: ...on sense when assembling or installing Wenger Corporation products If any questions or problems arise call the Wenger Corporation at 800 4WENGER 493 6437 or 1 507 455 4100 worldwide Manufacturer The Diva Air Transporter is manufactured by Wenger Corporation 555 Park Drive Owatonna MN 55060 800 4WENGER 493 6437 1 507 455 4100 wengercorp com European Representative See the EC Declaration of Conformi...

Page 3: ...rt acoustic towers The different types of acoustic tower that can be lifted and transported are identified in operating instructions The following standards have either been referred to or been complied with in part or in full as relevant ENISO 12100 2 Machinery Safety Basic concepts general principles for design Part 2 Technical principles and specifications EN 954 1 Machinery Safety Safety Relat...

Page 4: ...in damage to property or serious injury WARNING Safety Precautions Throughout this document you may find cautions and warnings which are defined as follows WARNING Failure to follow the instruction could result in serious injury or damage to property CAUTION Failure to follow the instruction could result in minor injury or damage to property Read all of these safety instructions before using the e...

Page 5: ...n before the earth connection is broken In the OFF position the electrical power supply is removed from the entire machine The electrical power supply is provided by the use of a standard power cord The standard power cord must be routed where there is no risk of personnel tripping and falling because it has been routed in areas where personnel are expected to walk It is recommended that cables sh...

Page 6: ...ee all parts of the machine while it is being maneuvered A second person is needed to determine whether there are other personnel who might be in the path of the machine This makes it possible for operators to safely maneuver acoustic towers The power switch is hand operated and located at the upper rear of the base shroud In this position it is easy to access and operate There is no need for adju...

Page 7: ...the acoustic towers without the need to reach or stoop and is not stressful Provided acoustic towers of the correct type are presented to the machine there should be no handling problems Operating instructions provide instruction on how to attach acoustic towers to an air transporter and how to check the security of acoustic towers so that they cannot come loose 1 To move the air transporter when ...

Page 8: ...ansporter will be moved Prevent cord interference or damage by having another person manage the cord while moving the towers Lifting Bracket Lifting Hook Air Transporter Caster Release Plate Two or more people must work together when moving an acoustic tower One person must always watch for obstructions on the stage and above the stage while a second person pushes the air transporter Always clear ...

Page 9: ...the others 6 Stop moving the acoustic tower so that a second person can make sure that the wing panels are locked in the storage position and that the wing doors are locked to the wing panels Always rotate and lock the tower wing panels to the storage position before moving the tower to or from the performance position CAUTION Never move a tower on an inclined surface or ramp WARNING Always clear ...

Page 10: ... from the acoustical tower until the lift hooks are clear of the tower lift brackets b Place a foot against the rear of the air transporter and tilt the front upward until the front caster locks into place down position c Move the air transporter to the next acoustical tower to be moved 10 Repeat these steps to move the remaining towers to their performance positions Never move a tower faster than...

Page 11: ... other panels besides those prescribed Crushing impact or entrapment as a result of failing to connect acoustic towers to the machine using a suitable means of attachment Crushing impact or entrapment should an air transporter be used to lift and transport a heavy load other than an acoustic tower and the machine fails structurally Exposure to any hazards on the machine as a result of operating th...

Page 12: ...Remove the new air beam from the package and make sure it s the same size as the damaged one being replaced on the air mover Note Feel through the fabric and measure the size of the wood backer 2 If the new air beam is not the same size as the old one within 13 mm contact Wenger Corporation before continuing Replacement Air Beam Current Air Beam ...

Page 13: ... lock nut from the front of both sides b Carefully lift the hood off and set it aside 2 Remove the hose clamp and disconnect the hose from the tee at the blower motor 3 Remove the twelve screws that attach the air beam to the support plate Air Beam Air Mover Hood Plastic Spacer Shoulder Bolt Lock Nut Plastic Spacer Shoulder Bolt Lock Nut Screws Support Plate Remove hose clamp and disconnect hose f...

Page 14: ...way from the support plate 4 Remove the hose coupler and valves from the air beam IMPORTANT The hose is glued to coupler and cannot be removed from the coupler The coupler must be removed from the original air beam and installed on the new air beam Screws Remove air beam and hose assembly Hose and Coupler Inlet Valve Flap Valve Socket ...

Page 15: ...new air beam in the same order as they were removed Secure in place with the existing screws 3 Feed the hose through the hole in the support plate and position the air beam to be parallel to the support plate 4 Tip the air mover upright Feed hose through hole 279 3 mm 11 0 125 Outline of board 178 3 mm 7 0 125 Screws Hose and Coupler Inlet Valve Flap Valve Socket Support Plate ...

Page 16: ... screws according to these measurements 5 Connect the hose to the tee at the blower motor and attach it using the original hose clamp 6 Replace the air mover hood using the original fasteners 74 3 mm 2 906 0 125 from board edge Air Beam Screws Support Plate Connect hose to tee and attach hose clamp 114 3 mm 4 5 0 125 from board edge ...

Reviews: