background image

  INSTRUCTION MANUAL

KNOW YOUR MICROMETER

SPECIFICATIONS

MODEL 10725

MICROMÈTRE NUMÉRIQUE

DIGITAL MICROMETER

  Measuring Range

  0 to 1 in. / 0 to 25 mm

  Resolution

  0.00005 in. / 0.001 mm

  Measuring Force

  5 to 10 N

  Power

  CR2032 Lithium Battery

  Power Consumption

  < 20 u A

  Operating Temperature

  32 to 104°F / 0 to 40°C

  Storage Temperature

  -4 to 76°F / -20 to 60°C 

INSTRUMENT CARE & SAFETY

       Follow the safety precautions below to reduce the risk of damaging your instrument. 

1. Avoid exposure to any liquids or excessive humidity.

2. Avoid exposure to electromagnetic fields or high voltages.

3. Avoid exposure to direct sunlight. 

4. Use and store the instrument within the recommended temperature ranges.

5. Do not drop or apply excessive force to the instrument. 

6. Do not attempt to disassemble the instrument.

7. Do not press the keys with a pointed object.

8. Use a dry soft cloth or cotton swab to clean the instrument. Ethyl alcohol can be used.  

Do not use solvents (such as acetone or benzene) to clean the instrument. 

OPERATION

INSTALLING THE BATTERY

One CR2032 Lithium battery is included with your instrument. Turn the battery cover counterclockwise to 

open. Insert the battery with the positive (+) side facing upward. Turn the battery cover clockwise to close.

NOTE: The instrument will automatically turn OFF if it is not used for five minutes to preserve battery 

power. Remove the battery if the instrument is not being used for an extended period of time.

"ON/OFF· · ·SET" BUTTON

"ABS· · ·in/mm" BUTTON

LCD DISPLAY

• Press and release - turns the tool ON/OFF
• Press and hold (4 secs) - resets reading to ZERO

• Press and release - switches between absolute 

measuring mode & relative measuring mode ("INC") 
• Press and hold (4 secs) - mm / inch conversion 

"INC"

Relative measuring mode

"in"

inch

"mm"

millimeter

ABS· · ·in/mm

ON/OFF· · ·SET

SPINDLE LOCK 

Turn the spindle lock clockwise to lock the instrument. Do not rotate the thimble or ratchet when the lock 

is engaged. Turn the spindle lock counterclockwise to unlock the instrument.

RATCHET & THIMBLE

Rotate the ratchet to make quick adjustments the spindle; rotate the thimble to make fine adjustments 

to the spindle. When you hear a clicking sound during the rotation of the thimble, that means the spindle 

and anvil have exerted adequate pressure on the subject and an accurate reading can be taken.

NOTE: 

When taking measurements, do not 

touch the measuring faces of the micrometer. 

The small amount of oil on your hands can 

affect the accuracy of your readings.

Thimble 
(Fine Adjustment)

ABS· · ·in/mm Button

ON/OFF· · ·SET Button

LCD Display

Ratchet 
(Quick Adjustment)

Anvil

Spindle Lock

Spindle

CLEANING THE MEASURING SURFACES

Wipe clean the anvil and spindle faces with ethyl alcohol prior to use to remove any oil, grease, or debris.