M
406 p/
n 2M
-3049
42
Owners M
anual HRCP-Serie
s
Hea
ted Cold
Pan
s
WIRING & REFRIGERATION DIAGRAMS
15
23
1
WATER FILL CONTROL
L1
N
L2
120/208-240V, 3 WIRE, SINGLE PHASE
3
3
5
4
1
27
8
9
10
11
12
28
26
13
14
15
10
21
24
25
18
19
20
SUPPLY VOLTAGE
L1-L2
REQUIRED NOMINAL
208 - 240 VAC
120 VAC
L2-N
3-WIRE 120/208-240VAC
HEAT
FILL
210 VAC
SENSING PROBE
COMPRESSOR
RECEIVER
5
CPR VALVE
29
MFS
NO
ELECTRICAL RATING
1.9
2.5
3.0
4.0
6.0
8.0
KW
3.8
5.0
6.0
8.0
120/208-240 VAC
10.4
9.0
208
240
7200
16.7
14.4
208
240
7300
33.3
28.9
208
240
7600
20.8
18.1
60 HZ
WARMER
L1 - L2
VOLTS
208
240
MODEL
HRCP
7400
33.3
28.9
208
240
7500
5.5
7.0
15.3
7.5
L2 - N
15.3
120
120
120
VOLTS
120
120
1/4
1/3
3/4
HP
1/2
3/4
REFRIGERATION
AMPS
R-134-A
R-404-A
R-404-A
TYPE
R-404-A
R-404-A
1-PH
REFRIGERANT
1-PH
AMPS
15
15
15
30
30
1.9
2.5
10.4
9.0
208
240
7100
5.5
120
1/4
R-134-A
15
BLACK
WATER
SUPPLY
MANUAL RESET
OVER-TEMP CUTOUT
THERMOSTAT
2
31
IMMERSION
ELEMENT
SECOND ELEMENT
FOR HRCP 7400
THRU 7600 ONLY
32
POWER
RELAY
WATER FILL
SOLENOID VALVE
HIGH
LOW
WATER LEVEL
PROBES
GREEN/YELLOW
WHITE
BLACK
WIRING DIAGRAM FOR
HRCP-7100 THRU 7600 W/AUTO WATER FILL
WHITE
YEL/GRN
SAFETY THERMOSTAT
SUPPLY
GROUND
REF.
LIGHT(WHT)
WARMER
LIGHT
(RED)
THERMOSTAT
7
WARMER
HEAT LIGHT
(RED)
C
HI
XL
P R O B E S
T2
T1
T3
L1
L2
L3
C1
C2
BLACK
G
ELECTRONIC
TEMPERATURE
CONTROL
C 120
C NO
MOISTURE
INDICATOR
EXPANSION
VALVE
CONDENSER
COIL
AIR
FLOW
FAN
FILTER/DRYER
LIQUID LINE
REFRIGERATION SCHEMATIC
OVERLOAD
WIRING
COMPARTMENT
CONDENSER
FAN MOTOR
COMPRESSOR
MOTOR
ELECTRONIC TEMPERATURE
CONTROL
FAN
MOTOR
RELAY
1
2
M
S
1
3
S
R
C
START AND RUN WINDINGS
WHITE
BLACK
START CAPACITOR
COMPRESSOR WIRING COMPARTMENT
25
26
4
7
REFRIGERATION COILS
L1
L2
T2
T1
HIGH PRESSURE
CUTOUT. FOR
HRCP-7400 ONLY
FUSE
FIELD WIRING
TERMINAL BLOCK
REFRIGERATION CONTACTOR