47
© Well Straler all rights reserved
14
Error codes
Error
code
Display
duration
Symptoms
Possible causes
F04
4 secs.
•
No pilot flame within 30
secs.
•
NOTE: After 3 failed
ignition sequences F06 is
displayed
•
No gas supply
•
Air in pilot supply line
•
No spark
•
Reversed polarity in
thermocouple wiring
F06
4 secs.
•
3 failed ignition
sequences within 5
minutes
•
Flame is not responding;
no pilot flame
•
No gas supply
•
Air in pilot supply line
•
No spark
•
Reversed polarity in
thermocouple wiring
•
Check for correct pilot orifice
F07
Until
batteries
are
replaced
•
Battery icon flashes on
remote control display
•
Low battery power in remote
F09
4 secs.
•
Flame is not responding
•
No electronic control of
flame
•
Down arrow button was not
pressed during pairing
•
Receiver and remote control are
not synced
F46
4 secs.
•
Flame is not responding
•
Intermittent response
•
No electronic control of
flame
•
No or bad connection between
receiver and remote control
•
No power at receiver (batteries
low)
•
Short communication range
(mains adapter faulty, remote
not communicating with
receiver)