35
© Well Straler all rights reserved
7.14
Automatic functional reduction
No communication for 3 hours:
Manual mode/Thermostatic mode/Program mode:
The gas valve switches the flame over to the pilot flame if the flame height has not been
changed for 3 hours. The appliance will function normally again once the communication
has been restored.
Receiver overheating:
All modes:
The gas valve switches the flame over to the pilot flame if the temperature in the receiver
exceeds 60 °C. The main burner will only burn again if the temperature drops below 60 °C.
7.15
Automatic power-off
Receiver batteries
If the batteries in the receiver are low, the system powers off the appliance completely.
Extinguishing of the pilot flame after longer inactivity
This ecological function stops gas consumption by automatically disabling the pilot flame
when the appliance has been inactive for a longer period. Thanks to this, gas consumption
can be reduced and therefore costs can also be reduced.
7.16
Replacing the batteries in the remote control
1.
Slide open the battery compartment of the remote control.
2.
Remove the old batteries and install 2 new
AAA
batteries. Avoid short circuits between
batteries and metal objects. Pay attention to the polarities of the batteries and the holder.
3.
Replace the cover of the battery compartment.
Batteries are covered by "minor chemical waste" and should not be disposed of with
the household refuse.
ONE BUTTON AND TWO BUTTON IGNITION
Change from one button (default setting) to two button ignition or vice versa by pressing and
holding the power button for 10 sec. immediately after installing batteries. ON is displayed
and 1 or 2 (One or Two Button Ignition) is flashing. When change is complete 1 changes to 2