34
© Well Straler all rights reserved
7.12
Operation via an external source
The appliance can be operated via an external source, such as an automation system, via a
connection to the receiver. The total length of the cable (available as an option (ref. 27020))
can be up to 8 metres.
Ignition:
Close contacts 1 and 3
simultaneously for 1 second.
High fire:
Close contact 1. The contact must be
closed for 12 seconds to run the
motor from terminal to terminal.
Low fire/Pilot flame:
Close contact 3. The contact must be
closed for 12 seconds to run the
motor from terminal to terminal.
Power off:
Close contacts 1, 2 and 3 simultaneously for 1 second.
Possible operating modes:
◼
Mode 1:
The external source has only an
On/Off
control.
The remote control controls all other functions.
◼
Mode 2:
The external source controls the room temperature.
The remote control must be in
Manual mode
. If the remote control is set to
Thermostatic mode
, the remote control will have priority over the external source.
7.13
My Fire app
The appliance can be operated using a smartphone by means of the
MY FIRE APP.
Before the app can be used, a
Wi-Fi Kit
needs to be connected to the receiver.
If
Thermostatic
,
Program
or
Eco mode
is enabled, the corresponding
icon is displayed and
“
APP
”
is shown on the remote control.
The modes can be operated in accordance with the descriptions in
the user manual of the
MyFire Wi-Fi Box
.
Mode
Close contacts
Ignition
1 and 3
High fire
1
Pilot flame 3
Power off 1, 2 and 3