5.5.1
Roof terminal kit (C31)
The roof terminal kit is used when the gas flue discharges to a sloping
roof. These roof terminals are suitable as combined passages for the
discharge of combustion gases and the supply of combustion air for
closed gas-fired appliances. The connection is made using concentric
tubes of Ø 100
–
Ø 150 (fixed or flexible).
5.5.2
Installing a roof terminal kit
1.
Determine the location of the roof terminal. With a tile roof the type of tiles must be
taken into account.
2.
Make a hole from outside for the roof terminal. Ensure there is no chance of sawdust
or dust getting into the appliance.
3.
Install the lead slate.
4.
Install the roof terminal carefully from outside through the roof.
5.
Get the roof terminal level using a spirit level.
6.
Put the supplied mounting bracket on the roof terminal and attach it to the roof
boarding. Do not tighten the mounting bracket yet.
7.
Construct the concentric flue gas system. Start from the appliance.
8.
Firmly secure the mounting bracket.