9
2.4.2.
Program overview
If you want to review the settings for either the
factory
program and/or your customized
program, you may do so by (in OFF-mode)
pressing the
PROG
button for 1 second. By
pushing this button repeatedly you can review
the complete program.
Press
SET
to return to the normal mode.
If you press the
PROG
button for 4 seconds then
you enter the programming process.
Press the
SET
button to cancel this.
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
-
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
-
+
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
-
+
+
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
-
+
-
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
+
-
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
+
-
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
+
-
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
+
OFF
MODE
RETURN
ON
RESET
FLAME+
FLAME-
REVIEW
BACK
TIMER
AHEAD
AUTO
MODE
FAN
-
+
2.4.3.
Program cancellation – return to factory settings
To cancel the customized program that you have entered and to return to the factory settings:
In OFF-mode, press and hold
PROG
and
SET
for a long period. The customized program will be cancelled when
P
appears on the display. You will also hear a peep at the same time. Press
SET
to return the LCD-screen to normal
state.
2.5
Operating your appliance
2.5.1.
Manual (ON/OFF)
Push the
UP-
and
+
buttons simultaneously until the LCD-screen displays
ON.
Together with
ON
the LCD-screen will
display
FLAME
and 1 flame symbols.
At this point the spark electrode will begin sparking to ignite the pilot for a period of maximum 60 seconds. As soon
as a flame is detected the sparking will stop, and after a few seconds the main burner will ignite. The flame height at
this stage will be
LO
. The appliance will burn as long as it is not turned off manually, regardless of the room
temperature.
REMARK
: In case of a new installation, it is possible that the pilot does not ignite after 60 seconds, due to air in the
gas pipes. In this case the appliance will shut down and turn to secure mode (red alert LED is lit). Before you can use
the appliance again it has to be reset. To reset the appliance press
OFF
on the transmitter, or
RESET
on the receiver.
To re-ignite: press the
UP
-
and
+
buttons until the LCD-screen displays
ON
. Repeat this procedure until there is no
more air in the gas pipes, and the pilot ignites.
Once the pilot is on and the main burner is burning low, it is possible to change the flame
height and the speed of
the fan with the
FLAME-/+
and
FAN
toggle keys:
Flame height (gradually adjustable):
push
UP/DOWN
Speed of the ventilator:
push
FAN
(LO- -HI)
To switch off the device, push
OFF
(
OFF
appears). The pilot as well as the main burner will be quenched.
After this, the fan will still turn for about 25 minutes, until the remaining heat is fully utilized.
*
only for devices equipped with a fan