Operating Instructions 

 
 

Type 

 

ProtectoSmart 

with Activated-Carbon 

 
 
 
 
 
 
 
 

Weldability sif

 

Peters House, The Orbital Centre 

Icknield Way, Letchworth Garden City 

Hertfordshire 

SG6 1ET 

Tel.: +44 (0) 845 862 2620 
Fax: +44 (0) 800 970 7757 

E-Mail: [email protected] 

www.weldability-sif.com 

Summary of Contents for ProtectoSmart

Page 1: ...oSmart with Activated Carbon Weldability sif Peters House The Orbital Centre Icknield Way Letchworth Garden City Hertfordshire SG6 1ET Tel 44 0 845 862 2620 Fax 44 0 800 970 7757 E Mail sales weldabil...

Page 2: ...ing the extractor fittings 7 5 2 Electrical connection of the unit 8 5 3 Connection of an air outlet pipe 8 6 Explanation of the controls 8 7 Maintenance 9 7 1 Changing of pre filter 9 7 2 Changing of...

Page 3: ...Suction arm with suction hood or connecting piece Lid Hand grip Filter housing Filter door Ventilator housing Ventilator door Pos 13 Pos 14 Pos 15 Pos 16 Pos 17 Pos 18 Pos 19 Pos 20 Pos 21 Pos 22 Pos...

Page 4: ...plete volume of air in the workshop is replaced However this method only achieves a small reduction in the level of pollution within the breathing space of the user The same applies to overhead extrac...

Page 5: ...s and odours will be refined Then the air is sucked in by the ventilator and recycled to the air in the workshop through the exhaust grid at the back of the unit Caution As soon as the resistance to t...

Page 6: ...if the earthing cable is not in perfect condition If external filter controls are used the control cable must be checked for possible damage before every operating session The unit must not be used i...

Page 7: ...e unit before commissioning 5 1 Attaching the extractor fittings The extractor fitting e g an extractor hose or an extractor arm must be mounted on the extractor spouts or the housing cover If an extr...

Page 8: ...t air To ensure this functionality an exhaust pipe must be connected on the air outlet grille on the back of the fan housing Pos 11 6 Explanation of the controls Pos 1 The main switch switches the fil...

Page 9: ...nts and when using an appropriate protective respiratory mask We recommend to use a respiratory mask to DIN EN 141 143 Protection class P3 The job of changing the filter elements should be executed by...

Page 10: ...e lid Pos 7 for possible damage Close the filter access door Pos 10 Connect the filter unit to the mains circuit 7 3 Changing of the activated carbon cassette As soon as odours appear the activated ca...

Page 11: ...een extracted we offer the following services Help with finding a waste disposal company in your vicinity On request we can supply a list of all waste disposal companies in Germany free of charge A se...

Page 12: ...cycle 100 Width x depth x height mm 665 x 681 x 1200 Weight without arm kg 95 Filter insert pre filter particle filter activated carbon cassette Filter performance 99 Noise level measured as per DIN...

Page 13: ...ollowing standards Directives on machine building 2006 42 EG Electromagnetic compatibility 2004 108 EG Directives on printing device 97 23 EG Directives on low voltage 2006 95 EG Applied harmonised st...