41
(1)
The illuminant should have cooled down before you remove
it.
(2)
Open the front panel and remove the grease filter (s. fig.
below).
(3)
Pull the old illuminant out of its holder and replace it by a new
one of the same kind and power carefully / 2,0 W max. (s. fig.
below).
(4)
Insert the grease filter and close the front panel.
Required minimum distance to surfaces
such as pot lids, oven cloths etc. to avoid
any hot parts and risk of fire.
--- m = 0,45 m
Only use self-shielded illuminants to avoid
hot parts, risk of fire and exposure to UV-
radiation.
6. Trouble shooting
Malfunction
Possible cause
Measure
The appliance does not work at all.
→
The plug of the appliance
is not connected to the
socket.
→
The plug has become
loose.
→
The socket is not supplied
with energy.
→
The fuse is switched off.
→
Check the corresponding
socket by connecting it
with another appliance.
→
Check the fuse box.
Light is on but motor does not work.
→
Ventilation damper
blocked.
→
Motor
mounting
defective.
→
Remove the blockage.
→
Replace the motor.
Abnormal motor-smells.
→
The motor defective.
→
Replace the motor