Part Number 000007661 Rev02 02/20
111
RF2300C/RFS2300C Troubleshooting
QUIETQUBE REMOTE AIR-COOLED MODELS WITH
REMOTE CONDENSING UNIT
Normal Operation
When the toggle switch is placed in the ON position the
following controls must be in the closed position before
the ice machine will start:
A. Bin Thermostat
B. High Pressure Cut-out Switch
C. Ice Chute Safety Switch
D. Low Pressure Switch
E. Low Water Level Switch
Placing the toggle switch in the ON position starts the
gear motor. After the rotation speed sensor verifies 10
minutes of correct rotation the time delay ends and the
liquid line solenoid valve opens.
• When the refrigerant pressure is high enough to close
the low-pressure control the contactor coil energizes
and the compressor starts.
• The refrigerant pressure will increase and close the
fan cycling pressure control and the condenser fan
motor starts.
The ice machine will continue to make ice until ice
contacts the bin thermostat and the liquid line solenoid
valve closes and the refrigeration system pumps down.
• The refrigerant pressure drops and the fan cycling
pressure control opens stopping the condenser fan
motor.
• When the refrigerant pressure is low enough to open
the low pressure control, the contactor coil is de-
energized and the compressor stops.
NOTE: The ice machine remains off until ice no longer
contacts the bin thermostat.
Summary of Contents for Manitowoc RCU1075
Page 2: ......
Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 22: ...THIS PAGE INTENTIONALLY LEFT BLANK 22 Part Number 000007661 Rev02 02 20...
Page 56: ...56 Part Number 000007661 Rev02 02 20...
Page 221: ...Part Number 000007661 Rev02 02 20 221 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 224: ...224 Part Number 000007661 Rev02 02 20 RF0300 AIR COOLED Refer to Nameplate for Voltage Rating...
Page 252: ...252 Part Number 000007661 Rev02 02 20 RNS0308 AIR COOLED Refer to Nameplate for Voltage Rating...
Page 260: ...260 Part Number 000007661 Rev02 02 20 RNS1000 AIR COOLED Refer to Nameplate for Voltage Rating...
Page 270: ...270 Part Number 000007661 Rev02 02 20 RF1200 RFS1200 WATER COOLED 1 2 3 4 5 6 7 8...
Page 272: ...272 Part Number 000007661 Rev02 02 20 RF2300 RFS2300 AIR COOLED 1 2 3 4 5 6 7 8 8...
Page 274: ...274 Part Number 000007661 Rev02 02 20 RF2300 RFS2300 WATER COOLED 1 2 3 4 5 6 7 8 8...
Page 282: ...282 Part Number 000007661 Rev02 02 20 RN0400 RN1000 RN1400 AIR WATER COOLED 1 2 3 4 5 6...
Page 286: ...286 Part Number 000007661 Rev02 02 20...
Page 287: ...Part Number 000007661 Rev02 02 20 287 THIS PAGE INTENTIONALLY LEFT BLANK...