42
Detailed Descaling and Sanitizing Procedure
UDP0080
Ice machine cleaner/descaler is used to remove lime scale
and mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
Step 1
Move the toggle switch to Off after ice falls
from the evaporator at the end of a Harvest cycle. Or, set
the toggle switch to Off and allow the ice to melt off the
evaporator.
,
Caution
Never use anything to force ice from the evaporator.
Damage may result.
Step 2
Remove all ice from the bin.
n
Warning
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner/Descaler
or Sanitizer.
,
Caution
Do not mix Ice Machine Cleaner/Descaler (9405463)
and Sanitizer (9405653) solutions together. It is a
violation of Federal law to use these solutions in a
manner inconsistent with their labeling.
Step 3
To start a cycle move the toggle switch to Wash.
Step 4
Wait until water flows over the evaporator
(about three minutes) then add the proper amount of
Manitowoc Ice Machine Cleaner/Descaler to the water
trough.
Model
Amount of Cleaner/Descaler
Part Number 9405463
UDP0080
1.5 ounces (45 ml)