2 of 6
Document Number: MSC-017 4/20
Subject: Restoring Ice Machine to Service Procedures
Remove splash shield
48” models.
Lift the splash shield up and
forward to remove.
Remove splash shields (2)
Dual Evaporator Models.
Grasp the top center of
splash shields. Lift up and
then out.
7. Remove water trough
Depress tabs on right and
left side of the water trough.
Allow front of water trough
to drop as you pull forward
to disengage the rear pins.
Refer to Step 12 for Dual
Evaporator Trough Removal.
8. Remove the water
level probe.
Pull the water level probe
straight down to disengage.
Lower the water level probe
to obtain access. The water
level probe can be descaled
and sanitized at this point
without complete removal.
If complete removal is
desired, disconnect the ice
thickness control wire from
the control board.
NOTE: Some models allow
disconnection of the wire
lead from the water level
probe. Lower the water
level probe until the wiring
connector is visible, then
disconnect the wire lead
connector from the water
level probe and remove
from the ice machine.
Refer to Step 11 for Dual
Evaporator Water Pump and
Water Level Probe Assembly
Removal.
9. Remove the water
pump.
Grasp pump and pull
straight down on pump
assembly until disengaged
and the electrical connector
is visible. Disconnect
the electrical connector.
Remove the water pump
assembly from ice machine.
Refer to Step 11 for Dual
Evaporator Water Pump and
Water Level Probe Assembly
Removal.