Subject: Restoring Ice Machine to Service Procedures

Remove splash shield 

48” models.

Lift the splash shield up and 

forward to remove.

Remove splash shields (2)  

Dual Evaporator Models.

Grasp the top center of 

splash shields. Lift up and 

then out. 

7.  Remove water trough

 Depress tabs on right and 

left side of the water trough. 

Allow front of water trough 

to drop as you pull forward 

to disengage the rear pins.

Refer to Step 12 for Dual 

Evaporator Trough Removal. 

8.  Remove the water 

level probe. 

Pull the water level probe 

straight down to disengage. 

Lower the water level probe 

to obtain access. The water 

level probe can be descaled 

and sanitized at this point 

without complete removal. 

If complete removal is 

desired, disconnect the ice 

thickness control wire from 

the control board.  

NOTE:  Some models allow 

disconnection of the wire 

lead from the water level 

probe. Lower the water 

level probe until the wiring 

connector is visible, then 

disconnect the wire lead 

connector from the water 

level probe and remove 

from the ice machine.
Refer to Step 11 for Dual 

Evaporator Water Pump and 

Water Level Probe Assembly 

Removal.

9.  Remove the water 

pump. 

Grasp pump and pull 

straight down on pump 

assembly until disengaged 

and the electrical connector 

is visible.  Disconnect 

the electrical connector. 

Remove the water pump 

assembly from ice machine. 

Refer to Step 11 for Dual 

Evaporator Water Pump and 

Water Level Probe Assembly 

Removal.