background image

15 

Figure 3-9 

Hardwire Connection

SteamCraft

DRAIN LINE 

COLD WATER SUPPLY LINES 

MAIN EXTERNAL 
POWER SWITCH 

1) Test Water Supply Lines

a. Check all connections for proper tightness.
b. Inspect the water connections inside the appliance. (Remove side panels if not already off.)
c. Open the water supply valves.
d. Check all lines and connections for leaks, both inside and outside the appliance.

E. Electric Power Supply

The electric supply must match all electrical and wiring requirements specified on the rating plate.

NOTE: The 24CEA10 Electrical Diagram is located inside of the Condensate Drip Trough.

The connection must be made as follows: 
1. Install a main disconnect switch and a separate fuse or breaker for this appliance as shown in

Figure 3-8. The fused disconnect switch is referred to as the “Main External Power Switch.”

2.

Do NOT use a power cord.

3. Make the electrical connection using flexible conduit, per local code. See Figure 3-9.

Figure 3-8 

Electrical Layout

Ground Lug 

Terminal Block 

Summary of Contents for Cleveland SteamCraft 24CEA10

Page 1: ...ation Installation Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual MODEL 24CEA10 For your future reference Model __________...

Page 2: ...nformer aux mesures de s curit normalis es de l industrie y compris mais sans s y limiter les r glementations de l OSHA les proc dures de d branchement verrouillage tiquetage relatives tous les servic...

Page 3: ...juste modificaci n servicio o mantenimiento puede ocasionar da os a la propiedad lesiones o muerte Lea detenidamente las instrucciones de instalacion y de operaci n antes de instalar poner a funcionar...

Page 4: ...de presi n Keep clear of pressure relief discharge Restez l cart de la soupape de suret Permanezca alejado de la descarga de presi n Do not lean on or place objects on the equipment Ne vous penchez p...

Page 5: ...e Start Up and Shutdown Summary Instructions 4 B Control Panel Switches 5 C Operating and Cooking Procedure 6 D Timed Mode Operating and Cooking Procedure 6 E Manual Mode Operating and Cooking Procedu...

Page 6: ...st for Dial Timer Control Panel 21 E Timer Test for Keypad Control Panel 22 F General Information about the Compartment Door Optional Steam Cut Off Switch 23 G Function Test for the Compartment Door O...

Page 7: ...as applicable When installed the appliance must be electrically grounded in accordance with the above b The Food Code latest edition of the Food and Drug Administration FDA 2 This equipment is to be i...

Page 8: ...IAL NUMBERS 1 Cleveland Range LLC assigns two product identification numbers to each appliance a model number and a serial number 2 Please provide this information when you contact Cleveland Range or...

Page 9: ...tment door and reduced cooking performance To help avoid injury When checking inside the cooking compartment always stand to the hinge side and away from the appliance and open the door slowly Inspect...

Page 10: ...s For ON OFF controls Turn ON the Compartment Steam switch 3 Turn ON the ON OFF switch See figure 4 1 The steam generators fill with water in about 6 minutes 4 Turn ON one or both cooking compartment...

Page 11: ...CONTROL PANEL SWITCH Figure 4 1 1 POWER ON and GENERATOR FILL Switch with Power ON Indicator Light This is the ON OFF switch Turn this switch ON to power the control panel and fill the steam generato...

Page 12: ...door to maintain cooking compartment temperature b If another use is not planned for more than half an hour leave the cooking compartment door open slightly c If the appliance will not be used again d...

Page 13: ...perating time from 0 to 60 minutes Turn the knob clockwise until it points to the required time When the Timer reaches 0 a buzzer sounds for 3 seconds The Dial Timer does NOT work in Manual Mode 2 TIM...

Page 14: ...er after it has been stopped The Timer must rest to zero 00 00 zeroed by pressing this key before a new time can be set 4 START STOP Key Press this key to start and stop the Timer Press and hold for 5...

Page 15: ...ndards blowdown must be performed at the end of each shift 3 Blowdown Procedure a Follow the Shut Down instructions in Chapter 4 b EITHER restart the appliance by following the Startup instructions in...

Page 16: ...nd lifting up and away from the door b Wipe the gasket assembly with a damp cloth c Wipe the inside of the door with a damp cloth d Rotate the gasket assembly 180 This makes the gasket last longer e R...

Page 17: ...l If this appliance is suspected to be out of level shut it down at once and call your qualified Cleveland Range authorized service agency immediately CHAPTER 6 GENERAL INSTALLATION INFORMATION A Insp...

Page 18: ...rances and the Exhaust Hood Refer to spec sheet for more details g KEEP THE APPLIANCE AREA FREE AND CLEAR OF COMBUSTIBLES h Proper air supply for ventilation is REQUIRED for and CRITICAL to safe effic...

Page 19: ...Check the quality of supply water before designing the water supply by contacting a local water treatment specialist for on premises water analysis d Softened or chlorinated water damages the steam ge...

Page 20: ...use the Separate Feed Water Supply Arrangement shown in Figure 3 3 Figure 3 2 Cleveland Range Single Water Supply Arrangement Figure 3 3 Cleveland Range Separate Water Supply Arrangement Conditioned i...

Page 21: ...ic Power Supply The electric supply must match all electrical and wiring requirements specified on the rating plate NOTE The 24CEA10 Electrical Diagram is located inside of the Condensate Drip Trough...

Page 22: ...connect the appliance s drain connection to any drain material that cannot sustain 180o F 6 Do NOT connect any other drain from any other equipment to the drain line of this appliance 7 Do NOT connec...

Page 23: ...es Ch 7 Test Supply Water Quality Warranty Ch 7 Water Supply Requirements Met Ch 7 Electric Power Requirements Met Rating Plate Ch 7 Installation Ch 7 Check Level Front to Back and Side to Side Ch 7 C...

Page 24: ...est Startup and Shutdown Instructions NOTE Perform this test before Startup Test Procedure A Startup Instructions 1 If not already done Test the water supply lines Leaks and pressure 2 Turn the Main E...

Page 25: ...r the Main External Power Switch OFF 2 Check the fuses or circuit breakers for proper size 3 Make sure the water supply line valves are open 4 Open the cooking compartment doors Check for proper insta...

Page 26: ...ater column float assembly are flushed with fresh water 7 Stop the blowdown cycle before it is complete by turning the ON OFF switch ON a The operating controls energize b The red ON indicator in the...

Page 27: ...The red indicator in the ON OFF switch turns OFF Automatic blowdown starts and runs for 3 minutes 2 After blowdown ends a Turn OFF the Main External Power Switch b Replace all panels and sheeting c Tu...

Page 28: ...ors 5 Set the TIMED MANUAL switch to TIMED a Press the number keys 1 0 0 0 b The display reads 10 00 ten minutes and zero seconds 6 Press the START STOP key The timer reads PAUS pause The cooking comp...

Page 29: ...1 Start the appliance with both cooking compartments in MANUAL mode 2 Wait for the cooking compartments to reach cooking temperature 3 Stand to the hinge side and back from the upper door and careful...

Page 30: ...ckage of the drain line can cause pressure buildup in the compartment s resulting in steam leaks around the door gasket s reduced performance and compartment implosion 2 To inspect the drain screens a...

Page 31: ...ase of eye contact immediately flush eyes with water for 15 minutes If irritation persists seek medical attention In case of skin contact wash with soap and water If inhaled remove to fresh air If bur...

Page 32: ...N OFF Models put the ON OFF selector Switch in the OFF Position 4 DO NOT start timer DO NOT HEAT APPLIANCE Water must be cold for descaling Open cooking compartment door s Leave cooking compartment do...

Page 33: ...FF to start 3 minute Automatic Blowdown to rinse generator 13 Replace descaling cap and close cooking compartment door s 14 Turn TIMED MANUAL switch to TIMED 15 Turn steamer ON OFF switch to ON and se...

Page 34: ...MANUAL or TIMED modes Water supply to steamer shut OFF Open water supply valves Door interlock switch not engaged or has failed if unit has this option Close door completely If problem persists see No...

Page 35: ...ed wiring See Note 1 Water is flowing out of steam ports into cooking compartment See Warning under Note 9 Water probes are dirty Turn OFF water supply to steamer and descale steamer manually with Cle...

Page 36: ...r Cleveland Range Please have the model number and serial number ready when calling Cleveland Range will not pay for warranty repairs by unauthorized maintenance and repair centers 2 Proper installati...

Page 37: ...m if needed Failure to follow these precautions can cause burns scalds and equipment damage EGG SIZE CHART Egg Size Time Medium 10 minutes Large 12 minutes Extra Large 12 minutes 3 When time is comple...

Page 38: ...itchencare com To learn how Welbilt Foodservice and its leading brands can equip you visit our global web site at www welbilt com then discover the regional or local resources available to you Every n...

Reviews: